Output Terminal Assignments; My Function Input Setting Assignments, And Parameter/Input - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

Table 8. Output Terminal Assignments, My Function Input Setting Assignments, and Parameter/Input
Setting Numbers for the FLA/B/C, O1A/O1B (OUT1), O2A/O2B (OUT2), OUT3 – OUT6, and R1 – R4.
Input
Param.
Setting
Setting
1000
0
Lower-Limit Frequency
1002
2
Upper-Limit Frequency
1004
4
Low-Speed Signal
1006
6
Acceleration/Deceleration Completion
1008
8
Speed Reach Signal
1010
10
Failure FL (All Trips)
1012
12
Failure FL (Except EF, OCL, EPHO, OL2)
1014
14
Over-Current (OC) Alarm
1016
16
ASD Overload (OL1) Alarm
1018
18
Motor Overload (OL2) Alarm
1020
20
Over-Heat Alarm
1022
22
Over-Voltage Alarm
1024
24
Main Circuit (MOFF) Under-Voltage Alarm
1026
26
Low-Current Alarm
1028
28
Over-Torque Alarm
1030
30
DBR Overload Alarm
1032
32
Emergency Off Active
1034
34
Retry Active
1036
36
Pattern Operation Switching Output
1038
38
PID Deviation Limit
1040
40
Run/Stop
1042
42
Serious Failure (OCA, OCL, EF, Phase Failure, etc.) 1130
1044
44
Light failure (OL, OC1, 2, 3, OP)
1046
46
Commercial Power/ASD Switching Output 1
1048
48
Commercial power/ASD switching Output 2
1050
50
Cooling Fan On/Off
1052
52
Jogging Operation Active (Jog Run Active)
1054
54
Panel/Terminal Board Operation Switching
1056
56
Cumulative Run-time Alarm
1058
58
ProfiBus/DeviceNet/CC-Link Communication Error 1232
1060
60
Forward/Reverse Switching
1062
62
Ready for Operation 1
1064
64
Ready for Operation 2
1068
68
Brake Release (BR)
1070
70
Alarm Status Active
1072
72
Forward Speed Limit (Torque Control)
1074
74
Reverse Speed Limit (Torque Control)
1076
76
ASD Healthy Output
1078
78
RS485 Communication Error
1080
80
Error Code Output 1
1082
82
Error Code Output 2
1084
84
Error Code Output 3
Note: Only positive logic is available for the listed parameters.
H9 ASD Installation and Operation Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Discrete Output Terminal Assignment Selections
Function
Input
Param.
Setting
Setting
1086
86
Error Code Output 4
1088
88
Error Code Output 5
1090
90
Error Code Output 6
1092
92
Specified Data Output 1
1094
94
Specified Data Output 2
1096
96
Specified Data Output 3
1098
98
Specified Data Output 4
1100
100
Specified Data Output 5
1102
102
Specified Data Output 6
1104
104
Specified Data Output 7
1106
106
Light Load
1108
108
Heavy Load
1110
110
Positive Torque Limit
1112
112
Negative Torque Limit
1114
114
External Rush Suppression Relay Activated
1118
118
Completion of Stop Positioning
1120
120
L-STOP
1122
122
Power Failure Synchronized Operation
1124
124
Traverse in Progress
1126
126
Traverse Deceleration Active
1128
128
Part Replacement Alarm
130
Over-Torque Alarm
1132
132
Frequency Command ½ Selection
1134
134
Failure FL (Except Emergency Off)
1222
222
My Function Output 1
1224
224
My Function Output 2
1226
226
My Function Output 3
1228
228
My Function Output 4
1230
230
My Function Output 5
232
My Function Output 6
1234
234
My Function Output 7
1236
236
My Function Output 8
1238
238
My Function Output 9
1240
240
My Function Output 10
1242
242
My Function Output 11
1244
244
My Function Output 12
1246
246
My Function Output 13
1248
248
My Function Output 14
1250
250
My Function Output 15
1252
252
My Function Output 16
1254
254
Always Off
Function
239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents