Discrete Input Terminal Assignment Selections And Descriptions - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

Table 5. Discrete Input Terminal Assignment Selections and Descriptions.
Sel. No.
NO NC
0
1
Unassigned — No operation.
Forward — Provides a Forward run command.
2
3
4
5
Reverse — Provides a Reverse run command.
6
7
Standby — Enables the Forward and Reverse operation commands.
8
9
Reset — Resets the device and any active faults.
10
11
Preset Speed 1 — Preset Speed 1 is used as the LSB of the 4-bit nibble that is used to select a Preset Speed.
12
13
Preset Speed 2 — Preset Speed 2 is used as the second bit of the 4-bit nibble that is used to select a Preset Speed.
14
15
Preset Speed 3 — Preset Speed 3 is used as the third bit of the 4-bit nibble that is used to select a Preset Speed.
Preset Speed 4 — Preset Speed 4 is used as the MSB of the 4-bit nibble that is used to select a Preset Speed.
16
17
Jog — This terminal activates a Jog for the duration of the activation. The Jog settings may be configured at
18
19
F262.
Emergency Off — Terminates the output signal from the drive and may apply a brake if so configured. The braking
20
21
method may be selected at F603.
DC Braking — Upon activation the drive outputs a DC current that is injected into the windings of the motor to
22
23
quickly brake the motor.
Accel/Decel Switching 1/Accel/Decel Switching 2 — Activating combinations of discrete input terminals
Accel/Decel Switching 1 and 2 allow for the selection of Accel/Decel profiles 1 – 4 as shown below.
See
F504
for more information on this terminal setting.
24
25
A/D SW Terminal
#1
0
0
1
26
27
1
1=Terminal Activated
V/f Switching 1/V/f Switching 2 — Activating combinations of discrete input terminals V/f Switching 1 and 2
allow for the selection of a V/f switching profile as listed below.
V/f Switching Terminal
28
29
#1
0
0
1
1
30
31
1=Terminal Activated
Note:
NO/NC = Normally Open/Normally Closed.
234
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Terminal Selection Descriptions
A/D Profile Selection
#2
0
1
1
2
0
3
1
4
V/f Selection
#2
0
1
1
2
0
3
1
4
The settings of the A/D selections 1 – 4 are performed
at F009/F010, F500/F501, F510/F511, and F514/
F515, respectively.
Accel/Decel profiles are comprised of the Accel/
Decel settings, Pattern, and Switching Frequency.
The 1 – 4 settings of the V/f Switching
selections are performed at parameters
F181.
H9 ASD Installation and Operation Manual
F260
F170

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd