11-8-3. Indoor Unit (Other Parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC) sensor
2
Remote controller
3
Louver motor
24BYJ48-A-080
4
Indoor fan motor
11-8-4. Outdoor Unit
No.
Part name
1
Compressor
07k Series
Model : NX66F0F-20D
10,13k Series
Model : NX89F0F-20D
2
Outdoor fan motor
(Model : WDF-340-A43-1)
3
4-way valve coil
(Model : DXQ-939)
4
Pulse modulating valve coil
(Model : PQ-M10012-000313)
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC (kΩ)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
White
1
1
Yellow
2
2
Yellow
3
3
Yellow
4
4
Yellow
5
5
Refer to 11-5-1. (3) and (4).
Measure the resistance value of each winding by using the tester.
Back
White
Red
Measure the resistance value of winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Measure the resistance value of winding by using the tester.
W
1
GR
COM
6
O
3
Y
GR BL
2
COM
- 84 -
Checking procedure
10°C
20°C
20.7
12.6
Position
1 to 2
1 to 3
1 to 4
1 to 5
Checking procedure
Position
NX66F0F-20D
Red - White
White - Black
Black - Red
Position
Red - White
White - Black
Black- Red
Resistance value
Position
Gray - White
Gray - Orange
Gray- Yellow
Gray- Blue
5
4
FILE NO. SVM-16003
25°C
30°C
40°C
10.0
7.9
4.5
Resistance value
200Ω ± 7%
Resistance value
NX89F0F-20D
3.19Ω
3.36Ω
Under 20ºC
Resistance value
16 to 51Ω
1450 ± 150Ω
Under 20°C
Resistance value
42 to 50Ω
42 to 50Ω
42 to 50Ω
42 to 50Ω
Under 20°C