Toshiba RAS-13BKV-E Service Manual page 22

Split type
Hide thumbs Also See for RAS-13BKV-E:
Table of Contents

Advertisement

7-2. Operation Data
<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/-
07BKV-E
10BKV-E
13BKV-E
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/-
7/6
07BKV-E
10BKV-E
13BKV-E
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.9 to 1.1
12 to 13
11 to 12
0.8 to 1.0
0.7 to 0.9
11 to 12
Heat exchanger
Standard
pressure
pipe temp.
P (MPa)
T1 (°C)
2.3 to 2.4
35 to 36
2.5 to 2.7
42 to 43
2.6 to 2.7
43 to 44
- 22 -
FILE NO. SVM-16003
Indoor
fan mode
T2 (°C)
47 to 48
High
High
52 to 53
49 to 50
High
Indoor
fan mode
T2 (°C)
0 to 1
High
0 to 1
High
0 to 1
High
Outdoor
Compressor
fan mode
revolution
(rps)
High
60
High
60
High
84
Outdoor
Compressor
fan mode
revolution
(rps)
High
69
High
69
High
75