10-5-2. Power Supply and Connecting Cable Connection
Power supply cable
Power supply cable
connect to L N
Connecting cable
Connecting cable
connect to 1 2 3
Power supply
cable
Connecting cable
Connecting cable
connect to L 2 3
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected fi rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Stripping length of the power
supply cable
Terminal block (L N 1 2 3)
N
L
10 mm
Earth line
Power supply
cable
Stripping length of the
connecting cable
Terminal block (L N 1 2 3)
3
10 mm
Earth line
Earth line
Connecting
cable
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Stripping length of the
connecting cable
Terminal block (L N 1 2 3)
3
2
L
10 mm
Earth line
Connecting cable
CAUTION
Terminal block
Earth line
50 mm
10 mm
Connecting
cable
70 mm
Earth line
50 mm
10 mm
70 mm
Terminal block
Earth line
50 mm
10 mm
70 mm
- 59 -
FILE NO. SVM-16003
Outdoor Unit
Connecting cable
Outdoor Unit
Connecting cable
Power cord
Earth line
Earth line
Connecting cable
Power cord
Earth line