Fault Repair; Display Message Summary; Table 060-2: Display Message Summary - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
3

Fault Repair

3.1

Display Message Summary

Display Message
Chamber empty - Please
refill
Please fill with fresh water
Please fill and replace the
water container
Please empty waste
container and then replace it
Please set the time of day
Please empty drip tray
Please use descaling funnel
and close the door
Please insert capsule plate
Please insert capsule
magazine
Please open the valve
Please close the valve
Confirm to start
Confirm to start
Empty
No. of uses until descaling
has to be done

Table 060-2: Display Message Summary

Cause
Selected chamber is empty
Reminder to fill water tank with
fresh water
Water tank empty or not
installed
Waste container full or not
installed
Appliance was disconnected
from main power
Drip tray full
Descaling funnel not installed
Capsule plate or capsule cage
not installed, or descaling
funnel still installed
Capsule magazine not
installed or sensor under the
drawer is dirty
Steam valve closed
Steam valve open
Descaling process or other
procedure needs to be
continued
Descaling process needs to be
continued
Selected chamber has not
been allocated a coffee type
The appliance counts the
number of servings (coffee, hot
water, steam) until it must be
descaled. Once this number
has been reached the
appliance is blocked and
cannot be used until descaling
is performed.
63
Technical Information
Remedy
Refill with coffee capsules
Fill water tank with fresh
water
Fill and install water tank
Empty waste container and
reinstall it
Set the time of day
Empty and clean drip tray
Remove capsule plate and
install descaling funnel in its
place
Remove descaling funnel, if
necessary, and install
capsule plate or capsule
cage
Install capsule magazine and
clean sensor with a cloth
Press steam lever down to
open
Slide steam lever upward to
close
Press right switch knob
Press right switch knob
Allocate a coffee to type to
the chamber
Perform the descale
procedure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cva 2652Cva 2660Cva 2662

Table of Contents