Technical Information
4.5

Capsule Magazine Motor Removal

1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the retaining screws (Figure 050-7, Item 1).
6. Remove the motor.
7. Remove the microswitch located beneath the motor.
8. Disconnect the electrical connections from the motor and the switch.

Figure 050-7: Capsule Magazine Motor Assembly

4.6

Capsule Transport Motor Removal

1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the capsule transport motor retaining screws (Figure 050-8, Item 1).
6. Remove the capsule transport motor.
7. Remove the microswitch located beneath the motor.
8. Disconnect the electrical connections from the motor and the switch.