CVA 265x & CVA 266x
2
Function
2.1
Appliance Status after a Power Failure
After a power failure, the appliance remains switched off (standby). The fault
memory, as well as all customer settings (except for time of day), remain
unaffected.
2.2
EPL 85x Power Electronic - Plug and Pin Connections
Figure 060-1: EPL 85x Connectors and Pin Locations
ST 1
ST 2
Pin
1
Contact Spring – Drip Tray Level
2
Contact Spring – Drip Tray Present
3
Contact Spring – Drip Tray (Common)
1
Water Tank Switch Contact
2
Water Tank Switch Ground
3
Door Switch Contact
4
Door Switch +5V
5
Capsule Magazine Motor +12V
6
Capsule Magazine Motor –12V
7
Capsule Magazine Optical Sensor +12V (pin 2 on sensor)
8
Capsule Magazine Optical Sensor –12V (pin 4 on sensor)
9
Capsule Magazine Optical Sensor GND (pin 1 on sensor)
10
Capsule Magazine Optical Sensor Output (pin 2 on sensor)
11
Capsule Magazine Motor Switch
12
Capsule Magazine Drawer Switch
13
Capsule Transport Switch
61
Technical Information
Use