Figure 010-1: Drip Tray Contact Springs; Figure 010-2: Drip Tray Contacts - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
Technical Information

Figure 010-1: Drip Tray Contact Springs

The two associated contacts are on the rear of the drip tray (Figure 010-2).
The power electronic registers whether the drip tray is present via the left
contact (Figure 010-2, Item 1) and the two "drip tray present" contact springs
(Figure 010-1, Item 1). When 13.5 fluid ounces (400 milliliters) residual water
is in the drip tray, both contacts (Figure 010-2, Items 1 and 2) touch the
water. The power electronic then detects a level of conductivity via the drip
tray level contact (Figure 010-1, Item 2) and registers that the drip tray is full.
The message Please empty drip tray is displayed.

Figure 010-2: Drip Tray Contacts

The drip tray present contact springs and the drip tray level contact spring
can be checked in the service mode; see Section 060-4.5.