Declaration Of Conformity; Power Supply - Bosch GIS 1000 C Professional Original Instructions Manual

Hide thumbs Also See for GIS 1000 C Professional:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
1) at 0.80 m measuring distance to surface
2) at an ambient temperature of 20–23 °C and an emissivity degree of >0.999
3) Information according to VDI/VDE 3511 Page 4.3 (publication date: July 2005); applies for 90 % of the measuring signal.
Deviations of the measuring results are possible in all ranges beyond the indicated dimensions in the Technical Data.
4) Refers to infrared measurement, see graphic:
5) For Bluetooth® low energy devices, establishing a connection may not be possible, depending on model and operating system. Bluetooth® devices
must support the SPP profile.
6) Limited performance at temperatures <0 °C
Technical data determined with battery from delivery scope.
The measuring tool can be clearly identified with the serial number 6 on the type plate.

Declaration of Conformity

We declare under our sole responsibility that the product de-
scribed under "Technical Data" complies with all applicable
provisions of the directives 2009/125/EC (Regulation
1194/2012), 1999/5/EC, 2011/65/EU including their
amendments and is in conformity with the following stand-
ards: EN 61010-1:2010-10, EN 60825-1:2014-08,
EN 300 328 V1.8.1:2012-06,
EN 301 489-1 V1.8.1:2008-04,
EN 301 489-1 V1.9.2:2011-09,
EN 301 489-17 V2.2.1:2012-09, EN 62479:2010-09.
Technical documents at:
Robert Bosch GmbH, PT/ETM9,
70764 Leinfelden-Echterdingen, GERMANY
Henk Becker
Executive Vice President
Engineering
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 16.04.2015
Bosch Power Tools
1 m
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
2 m
Assembly

Power Supply

The measuring tool can either be operated with commercially
available batteries or with a Bosch lithium-ion battery pack.
Article number 3 601 K83 370: The measuring tool can be
operated only with conventional batteries.
Operation with Batteries
(not for article number 3 601 K83 370) (see figure A)
The batteries are inserted into the battery adapter.
 The non-rechargeable battery adapter is intended only
for use in designated Bosch measuring tools and must
not be used with power tools.
To insert the batteries, slide the cover 27 of the battery
adapter into the battery port 29. Place the batteries in the
cover as per the illustration on the sealing cap 28. Slide the
sealing cap over the cover until you feel it engage and it is flush
with the handle of the measuring tool.
To remove the batteries, press the unlocking but-
tons 3 of the sealing cap 28 and pull off the sealing
cap. Take care that the batteries do not fall out. To
do so, hold the measuring tool with the battery
port 29 facing upward. Remove the batteries. To
remove the inside cover 27 from the battery port
29, reach into the cover and pull it out of the measuring tool
by applying light pressure to the side wall.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
 Remove the batteries from the measuring tool when
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
English | 23
5 m
1 609 92A 0XP | (17/4/15)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents