437
Info.
Started to change the primary volume for the indicated replication set to the indicated volume.
Recommended actions
No action is required.
438
Info.
Completed changing the primary volume for the indicated replication set to the indicated volume.
Recommended actions
No action is required.
439
Error
Failed to change the primary volume to the indicated volume for the indicated replication set. This can
occur for several reasons, such as:
The volume is not in the replication set.
Configuration tag or configuration data not found.
The retry limit has been reached.
Recommended actions
Verify that the specified volume is part of the replication set.
Verify that there are no network issues preventing communication between the local and remote storage
systems.
440
Warning
Retrying a replication due to an error on the indicated secondary volume.
This can occur for several reasons, such as:
The cache request was aborted.
The cache detected that the source or target volume is offline.
The cache detected a media error.
The snap pool is full.
The communication link is busy or experienced an error.
The snapshot being used for the replication is invalid.
There was a problem establishing proxy communication.
The replication is being automatically retried according to policies in place. If the issue is resolved before
retries are exhausted, the replication will continue on its own; otherwise, it will go into a suspended state
unless the policy is set up to retry forever.
Recommended actions
If any of the above problems exist, resolve them.
441
Error
Failed to forward an add-volume request for a volume in a replication set. The secondary volume cannot
be fully added to the replication set.
Recommended actions
Remove the indicated secondary volume from the replication set.
HP P2000 G3 MSA System Event Descriptions Reference Guide
53