356
Warning
This event can only result from tests that are run in the manufacturing environment.
Recommended actions
•
Follow the manufacturing process.
357
Warning
This event can only result from tests that are run in the manufacturing environment.
Recommended actions
•
Follow the manufacturing process.
358
Critical
All PHYs are down for the indicated disk channel. The system is degraded and is not fault-tolerant because
all disks are in a single-ported state.
Recommended actions
• Turn off the power for the controller enclosure, wait a few seconds, and turn it back on.
• If the condition doesn't persist (that is, if event 359 has been logged for the indicated channel), no
further action is required.
• If the condition persists, this indicates a hardware problem in one of the controller modules or in the
controller enclosure midplane. For help identifying which FRU to replace, see "Resources for
diagnosing and resolving problems" in the SMU help for the System Events panel, or the CLI help
for the show events command.
Warning
Some, but not all, PHYs are down for the indicated disk channel.
Recommended actions
• Monitor the log to see whether the condition persists.
• If the condition doesn't persist (that is, if event 359 has been logged for the indicated channel), no
further action is required.
• If the condition persists, this indicates a hardware problem in one of the controller modules or in the
controller enclosure midplane. For help identifying which FRU to replace, see "Resources for
diagnosing and resolving problems" in the SMU help for the System Events panel, or the CLI help
for the show events command.
359
Info.
All PHYs that were down for the indicated disk channel have recovered and are now up.
Recommended actions
•
No action is required.
360
Info.
The speed of the indicated disk PHY was renegotiated.
Recommended actions
•
No action is required.
HP P2000 G3 MSA System Event Descriptions Reference Guide