3.4.3

Gamma balance adjustment

The gamma balance is adjusted by adjusting the density at the Black Mode. The adjustment is per-
formed by selecting its density area from the following: low density, medium density and high density.
Language and screen
Photo
Text
(PS)
(PS)
596-0
597-0
596-1
597-1
596-2
597-2
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the codes to be adjusted (language and screen) and press the [ENTER] button.
(3)
Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[ENTER] button.
0: Low density (L) 1: Medium density (M) 2: High density (H)
(4)
Key in the adjustment value. (To correct the value once keyed in, press [CLEAR] button.)
(5)
Press the [ENTER] button to store the value in memory.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Let the equipment restart and perform printing job.
(8)
If the image density has not been attained, repeat step (1) to (7).
e-STUDIO165/167/205/207/237
ADJUSTMENT
Photo
Text
(PCL)
(PCL)
598-0
599-0
Low density
598-1
599-1
Medium density
598-2
599-2
High density
3 - 28
06/04
< Adjustment Mode (05) >
Item to be adjusted
The larger the value is, the
density of the item to be
adjusted becomes darker.
Acceptable values:
0 to 255. (Default: 128)
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved