Activating and altering the operating
hours counter for the charcoal filter —
(in recirculation mode)
The charcoal filter is needed for the
recirculation mode.
On delivery, the operating hours counter
for the charcoal filter is switched off.
For recirculation mode, the operating
hours counter needs to be set to suit
the type of cooking you do:
^ Press the On/Off sensor s to switch
the fan off.
^ Press the + symbol and the operating
hours control l— at the same time.
The charcoal filter symbol — of the
operating hours control and one of the
fan levels will flash.
The 1 to IS sensors indicate the time
set:
1 = 120 hours
2 = 180 hours
3 = 240 hours
IS = deactivated
^ Press the – symbol to select a shorter
operating time, or the + symbol to
select a longer operating time.
^ Confirm the selection by pressing the
operating hours control l—.
All the indicator lamps will go out.
If you do not confirm your selection
within 4 minutes, the rangehood will
automatically revert to the original
setting.
Reading the filter operating hours
counter
To check the percentage of time set
already used:
^ Press the On/Off sensor s to switch
the fan on.
^ Press and hold the operating hours
control l—:
– Once, to read the grease filter
operating hours. The grease filter
symbol l lights up.
– Twice, to read the charcoal filter
operating hours. The charcoal filter
symbol — lights up.
One or more of the fan power level
indicators will flash.
The number of flashing sensors
indicates the percentage of the
operating time which has already been
used up.
Indicator 1
Indicators 1 and 2 = 50 %
Indicators 1 to 3
Indicators 1 to IS
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.
Operation
= 25 %
= 75 %
= 100 %