GE GEK-36150 terminet 300 Operator's Manual page 46

Table of Contents

Advertisement

Operating Characteristics ·
PRINTER OPERATION
Normal Single
Linefeed*
Repeated line feeds
Backspace**
Startup***
TIME DELAY AND
11
FILL
11
CHARACTER CHART
FOR THE TermiNet 300 PRINTER
APPROXIMATE
INTERVAL IN
INTERVAL BETWEEN
Ml LLISECONDS
Last char. on old line
300
and first char. on
new line.
(a) Last char. on
350
old line and second
LF code.
(b) Subsequent LF
67
codes.
Printing and then
230
reprinting in same
position.
Commanding motor
430
on and printing.
NON-PRINTING
FILL CHARACTERS
30 cps
15 cps
10
6
2
8
3
2
6
3
12
6
GEK-36150
PLACEMENT OF
cps
FILL CHARACTERS
0
After line feed code.
After first line feed
code.
0
After the second and
subsequent line feed
codes.
2
After the backspace
code.
4
After ••Motor On"
code.
Shutdown****
Last data char.
300
9
4
3
Between last data
character and "Motor
Off" code.
Vertical Tab
VT or FF com-
mand and 1st
character.
------------~-----------------L---------------
9+
4+
3+
.75/
.38/
.25/
line
line
line
300
+
(27 x No. of Lines)
=
Required Time Delay in Milliseconds
-----------~----------~-----~L
__________________________ _
Red and Black Printing
Before ESC Code
300
9
5
3
Before and after changing
After ESC Code
50
2
ribbon colors
*If there is no CR, one "fill" character should be added to that shown.
**If BACKSPACE code is used more than once, it may take the place of "fill" characters; e.g., at 30 cps, to type and
underscore "AND", send A N D BS BS BS fill fill fill - - - .
The delay is required to insure hammers have
recovered from the previous actuation.
***The TermiNet 300 Printer will go from a motor off state to a printing or "ON LINE"
state
in response to the two
code sequence ESC h or H, or also in the case of automatic motor on from the Data Set.
The delay is required
to allow the motor to come up to speed.
****The TermiNet 300 Printer will go from a printing "ON LINE" state to a motor off state in response to the two
code sequence ESC
j
or
J,
by the EOT code (when jumpered), or also in the case of automatic motor off from the
Data Set.
The delay that precedes the motor off command is required to allow time to print any characters that
are in memory waiting for the proper registration of the hammers and belt.
(1)
Example:
6-6
At 30 cps with
~
line of VT:
[300 MS
+
(27 MS x 1)]
=
327 MS of required time delay
30 char/sec
=
33.3 MS/char
Fills required = 327 MS.
f
33.3 MS/char.
=
9.85 CHARACTERS of Fill's
10 FILL's (always round off to next higher number).

Advertisement

Table of Contents
loading

Table of Contents