Advertisement

^ Take the containers out of the
washer-disinfector.
^ Unscrew and remove the siphon
tube.
^ Fill the container with the agent
required.
^ Insert the siphon tube into the
container and tighten it securely.
Once the storage containers have been
filled the relevant message goes out.
Dispensing liquid chemical agents

"Check dispensing system [X]"

The current programme will be
interrupted.
^ Check the container referred to in the
message and the dispensing hoses.
[x] The display will show the number of the
dispensing system instead of the X.
^ If necessary, refill an empty container
or replace it with a new, full
container.
^ Vent the dispensing system hoses
referred to in the display using the
appropriate Service programme.
The level query for dispensing
systems which are not being used
can be turned off to avoid the error
message (see "Machine
functions / container lance" in the
Programming manual supplied with
the washer-disinfector).

Venting the dispensing system

If a dispensing system has been
emptied completely, it must be vented
after the container has been filled.
^ Select the appropriate Service
programme, e.g.
^ Press the Start button h.