BURLEY G4111 ACUMEN
FLUELESS GAS HEATER
INSTALLATION, SERVICING
& USER INSTRUCTIONS
WITH NATURAL GAS G20
OR LPG PROPANE GAS G31
(REFER TO RATING LABEL)
For the following countries: GB, IE
LEAVE THESE INSTRUCTIONS WITH THE USER
BURLEY WITIHIN 7 DAYS OF FITTING.
PROOF OF SERVICING MUST BE RETAINED
FITTER INVALIDATES THE WARRANTY
web:
www.burley.co.uk
G4111InstUser
G20/31
Issue JAN08 – v.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G4111 ACUMEN and is the answer not in the manual?

Questions and answers

Summary of Contents for Burley G4111 ACUMEN

  • Page 1: User Instructions

    TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO BURLEY WITIHIN 7 DAYS OF FITTING. A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED BY A CORGI ENGINEER DURING THE FIRST YEAR OF OWNERSHIP.
  • Page 2: Appliance Data

    INTRODUCTION Thank you for choosing this burley product. All of our products carry a CE mark which is awarded by an independent test house (notified body) and shows the fires have been type tested to meet the essential requirements of the European Gas Appliance Directive and the appropriate British Standards.
  • Page 3: Unpacking The Appliance

    UNPACKING THE APPLIANCE Carefully examine the carton for damage before unpacking. If it is obviously damaged, consult the supplier as to whether to proceed with the installation. Make sure the carton is stood upright and open the top. Remove the cardboard top fitting and place to one side;...
  • Page 4: Gas Supply

    Soft furnishings, decorations and loose wall coverings etc. must not be placed within 1 metre of the appliance and its convection outlets (see 5.0). Be aware of curtains etc which could be blown towards the appliance. On no account should glass mirrors or picture frames or any electrical equipment e.g. plasma screen TV’s be fitted or positioned on the wall above the appliance as the heat rising could damage them.
  • Page 5: Site Requirements

    ‘pull’ to develop behind the appliance which could disturb the flame picture. To prevent this, the void areas should be closed off as shown in the instructions for each method. Alternatively Burley supply a Cavity Box part no CAV4111. 5.1. Fireplace opening The appliance requires an opening with the following minimum dimensions.
  • Page 6 PREPARATION OF APPLIANCE AND FIXING METHOD Unpack the appliance and ensure it is correctly marked for the gas it is to be used with (see data badge). Take the appliance components and lay them out in an ordered manner. To prevent damage to the decorative frame and ceramic fire bed components (logs) place safely to one side.
  • Page 7 Push the fire box into the opening and centralise. Mark on the wall the position of the five holes in the fire box frame (Fig. 5). Withdraw the fire box, drill and plug the holes in the wall and re-fit the fire box whilst feeding the gas supply pipe into the appliance.
  • Page 8: Installation Method

    2 – Inserted partially into a cavity wall inner leaf or opening in wall 3 – Fitted into an existing fireplace or builders opening Note - Burley Appliances do not recommend fitting into the inner leaf of timber framed buildings. A false chimney breast / deep surround or false wall should be provided Fig.
  • Page 9 7.1.4 A suitable non combustible support platform shall be constructed within the enclosure for the appliance to sit upon. 7.1.5 Ensure that the wall around the opening and the base are flat and level. 7.1.6 Finally fit a non combustible back panel against the enclosure and fit any fire surround. Due note shall be taken of the recommendations specified in section 5.
  • Page 10 7.2.1 Decide on the location of the appliance taking account of any wiring or pipe work that may be running within the wall, and mark the wall for the fire place opening to the dimensions specified in section 4.2. 7.2.2 It is important to consider any precautions necessary to maintain the structural character of the wall.
  • Page 11: Complete The Assembly

    8.0 COMPLETE THE ASSEMBLY Fuel Bed Arrangement It is important for clean burning that the fuel bed components are correctly located as detailed. Do not use with incorrectly fitted, broken, or any other fuel bed components than those supplied with the product. 8.1.1 Carefully place the rear (largest) log piece on the support platform behind the burner.
  • Page 12 8.1.4 Place the remaining log to the right hand side of the fuel bed to bridge the front and rear log pieces. The stubby branch should nestle down and be located in the notch on the right of the rear log piece.
  • Page 13: Commissioning And Operation

    The inlet pressure must be within +/- 1.0 mbar of specification with all gas appliances in the house switched on and also with just the Burley appliance operating. If outside of tolerance the fault is most likely to be in the installation pipe work or service governor at the meter. A ‘lazy’ service governor can be the cause of pilot light problems if the problem is not spotted and rectified.
  • Page 14 It can be accessed through a flap on the back of the handset. The fire is fitted with a special 7.2volt Lithium battery available from your retailer or from Burley Appliances on 01572 756956. In normal use, this will last between 6 and 9 months. It can be changed by simply sliding it out of its housing under the fire, undoing the connector block and carefully replacing with a new one.
  • Page 15: Thermostat Operation

    10.2.6 To alternate between high and low flame use the flame buttons on the right hand side of the handset. 10.2.7 To turn the fire OFF press the ● button on the top left hand side of the remote handset. 10.2.8 The fire is fitted with a comfort thermostat behind the ash pan door and it is possible to set this to modulate the fire between off and on.
  • Page 16 how to adjust the thermostat for desired comfort levels. The user shall also be made aware of the precautions to prevent blockage of any purpose made room ventilation, and the need to keep soft furnishings away from the appliance. The outlet grille and glass on the appliance are working surfaces. On no account should these be covered or obstructed.
  • Page 17 Carefully withdraw the catalyst vent panel and examine the condition of the two catalysts both from the top and from inside the unit. If any damage or cracking of the catalysts is evident, replace. DO NOT ALLOW THIS APPLIANCE TO BE OPERATED WITH DEFECTIVE CATALYSTS. Carefully remove the ceramic fuel bed components.
  • Page 18 Burley Appliances are the only company to bench run and thoroughly test every single Flueless gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the factory in perfect working order.
  • Page 19 • Please read this sheet even if you have fitted our fires before. • Please leave this sheet with the customer as reference for future servicing of the appliance. • Please explain to the customer how the fire works and the details and facts listed on this sheet, particularly what the catalyst does and doesn’t do.
  • Page 20 After the equivalent of 30 years of use, the catalytic converter is as efficient as it was when brand new. Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency.
  • Page 21 9. Gas rating of Burley Fluless Appliances Burley’s Flueless Gas Appliances are all gas input rated in the factory and undergo further line tests for combustion, sooting and visual performance. For Installers who wish to gas input rate appliances we need to establish tolerances for pass and fail.
  • Page 22 The appliance has been used solely in accordance with the instruction book. • Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by incorrect pressure or gas, incorrect installation, operator error, neglect or abuse.