Burley ENVIRON Installation, Servicing & User Instructions

Flueless gas heater

Advertisement

FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON WITH NATURAL GAS G20
Legislation and regulations do change over time
This product is not suitable for primary heating purposes.
LEAVE THESE INSTRUCTIONS WITH THE USER
TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER
MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO
A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED
BY GAS SAFE ™ REGISTERED INSTALLER (FORMERLY CORGI) DURING THE FIRST YEAR OF
FAILURE TO HAVE THIS APPLIANCE FITTED BY GAS SAFE™ REGISTERED INSTALLER (FORMERLY
Burley Appliances Ltd,
Lands End Way, Oakham, Rutland, LE15 6RB
Telephone: +44 (0)1572 756956 Fax: +44 (0)1572 724390
e-mail:
info@burley.co.uk
ENVIRON/EMPATHY
G4240 – 69 MODEL
FLUELESS GAS HEATER
INSTALLATION, SERVICING
& USER INSTRUCTIONS
OR LPG PROPANE G31
(REFER TO RATING LABEL)
For the following countries: GB, IE
EVEN IF YOU HAVE FITTED THESE FIRES BEFORE,
PLEASE FOLLOW THESE INSTRUCTIONS STEP BY STEP.
BURLEY WITHIN 7 DAYS OF FITTING.
OWNERSHIP. PROOF OF SERVICING MUST BE RETAINED
CORGI) FITTER INVALIDATES THE WARRANTY
web:
www.burley.co.uk
G4240Inst
G20/31
Issue March 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENVIRON and is the answer not in the manual?

Questions and answers

Summary of Contents for Burley ENVIRON

  • Page 1 TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO BURLEY WITHIN 7 DAYS OF FITTING. A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED BY GAS SAFE ™ REGISTERED INSTALLER (FORMERLY CORGI) DURING THE FIRST YEAR OF OWNERSHIP.
  • Page 2 INTRODUCTION Thank you for choosing this burley product. All of our products carry a CE mark which is awarded by an independent test house (notified body) and shows the fires have been type tested to meet the essential requirements of the European Gas Appliance Directive and the appropriate British Standards.
  • Page 3: Lighting Procedure

    LIGHTING PROCEDURE. Identify the control valve fitted to the appliance and follow the appropriate instructions. Total Control Ensure that the ON/OFF switch is in the ON position ( ) & that the manual knob is also pointing downwards towards its ON position (see below). ON/OFF Switch Manual Knob...
  • Page 4 Battery Replacement Handset On the back of the handset remove the battery cover by pressing down the top of the cover & sliding it down. Remove & unclip the old battery & replace with a new PP3 9 volt battery. Receiver Unit (located under burner) Remove the heat shield surrounding the unit.
  • Page 5 MANUAL CONTROL There are 2 control knobs on the appliance. The right hand one controls On/Off and pilot/main burner. The left hand one is the comfort level thermostat which turns the fire down once the indicated temperature is reached. If during use the pilot is alight but the main burner is not lit, check the thermostat position and if necessary select a warmer setting.
  • Page 6: Slide Control

    SLIDE CONTROL 1.11 1. Press the control lever firmly down to the bottom of its travel and listen for the spark generator clicking which should light the pilot. 2. Continue to hold down for a further 10 seconds. 3. If the pilot fails to stay alight, slide the control lever to the top of its travel (off) & wait for 3 minutes &...
  • Page 7: Technical Data

    *The inlet pressure must be within +/- 1mBar of specification with all gas appliances in the house switched on and also with just the Burley appliance operating. If outside of this tolerance the fault is most likely to be in the installation pipe work or service governor at the meter. If the problem is the meter governor, this is the property of the gas service provider (such as Transco / National Grid 0800 111999 or Bord Gais) and they should be called to rectify this.
  • Page 8: General Requirements

    The installation must also be in accordance with the relevant parts of local and national building regulations and in accordance with BS5871 pt4 except where Burley instructions state differently. For the Republic of Ireland, reference should be made to IS813 and ICP3 and any guidance notes from Bord Gais.
  • Page 9: Installation Instructions

    Note: Burley manufacture purpose made surrounds, which have been specially tested with the appliance for compatibility. (This includes the wooden hearth) If a Burley Surround is used then the fires must be installed as supplied with the 60mm spacer fitted.
  • Page 10 The hearth and back panel must be made from a non-combustible material although ‘lightweight’ and tiled surrounds can be used provided they have a minimum heat rating of 150 c. Consideration should be given to the effect of expansion and contraction caused by temperature.
  • Page 11: Preparing The Appliance

    PREPARING THE APPLIANCE Unpack the appliance (see 2.0). Ensure appliance is correctly marked for the gas it is to be used with. Take the appliance components and lay them out in an ordered manner. To prevent damage the decorative trim, fret, coals and ceramic fire bed components can be placed safely to one side.
  • Page 12 through lower holes and push fully back into place and secure. Note if the fire opening / hearth are not level remedy this, or alternatively pack under the appliance base to prevent the top of it leaning away from the fireplace. Fully purge pipes of air and any debris and connect the gas supply to the 8mm elbow on the fire.
  • Page 13 Call outs to fires with incorrect pressures will be chargeable. BURLEY APPLIANCES IS THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY SINGLE GAS FIRE IT PRODUCES. BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER.
  • Page 14 I.e. pressure, model, room size and Gas Safe™ registered installer (formerly CORGI) Number If you have any questions or the fire is not operating correctly, phone the Burley help- line BEFORE you leave the installation.
  • Page 15: Servicing Instructions

    SERVICING INSTRUCTIONS As with all gas appliances the unit must be serviced at least once per year, preferably at the beginning of the heating season. All servicing must be carried out by a qualified service person. Before commencing any servicing, ensure that the gas is turned off to the appliance and that the appliance is cool.
  • Page 16: Parts List

    Burley Appliances are the only company to bench run and thoroughly test every single Flueless gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the factory in perfect working order.
  • Page 17 After the equivalent of 30 years of use, the catalytic converter is as efficient as it was when brand new. Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency.
  • Page 18 Burley Appliances Ltd - Domestic Guarantee Conditions We pride ourselves on the quality of service we deliver to our customers and all Burley Appliances’ products carry a fully inclusive 12-month parts and labour guarantee. This guarantee is extended by another 12 months free of charge provided that your appliance is serviced by a Gas Safe ™...
  • Page 19 Gas rating of Burley Flueless Appliances Burley’s Flueless Gas Appliances are all gas input rated in the factory and undergo further line tests for combustion, sooting and visual performance. For Installers who wish to gas input rate appliances we need to establish tolerances for pass and fail.
  • Page 20 Burley Magiglo fires are protected by UK patents 2193802, 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd, Lands’ End Way, Oakham, Rutland, LE15 6RB Tel: 01572 725570 Fax: 01572 724390 www.burley.co.uk Email: info@burley.co.uk Page 20 of 20...

This manual is also suitable for:

Empathy