ASTUTE G4113
FLUELESS GAS HEATER
INSTALLATION, SERVICING
& USER INSTRUCTIONS
NATURAL GAS G20
OR LPG G30/G31
(REFER TO RATING LABEL)
For the following countries: GB, IE
This product is not suitable for primary heating purposes.
LEAVE THESE INSTRUCTIONS WITH THE USER
BURLEY WITHIN 7 DAYS OF FITTING.
PROOF OF SERVICING MUST BE RETAINED
(FORMERLY CORGI) INVALIDATES THE WARRANTY
web:
www.burley.co.uk
G4113InstUser
G20/31
Issue: May2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASTUTE G4113 and is the answer not in the manual?

Questions and answers

Summary of Contents for Burley ASTUTE G4113

  • Page 1 TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO BURLEY WITHIN 7 DAYS OF FITTING. A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED BY A GAS SAFE ™ REGISTERED INSTALLER (FORMERLY CORGI) DURING THE FIRST YEAR OF OWNERSHIP.
  • Page 2: Appliance Data

    INTRODUCTION Thank you for choosing this Burley product. All of our products carry a CE mark which is awarded by an independent test house (notified body) and shows the fires have been type tested to meet the essential requirements of the European Gas Appliance Directive and the appropriate British Standards.
  • Page 3: On/Off Switch

    LIGHTING PROCEDURE. Identify the control valve fitted to the appliance and follow the appropriate instructions. Total Control Ensure that the ON/OFF switch is in the ON position (-) & that the manual knob is also pointing downwards towards its ON position (see below). ON/OFF Switch Manual Knob...
  • Page 4 Battery Replacement Handset On the back of the handset remove the battery cover by pressing down the top of the cover & sliding it down. Remove & unclip the old battery & replace with a new PP3 9 volt battery. Receiver Unit (located under burner) Remove the heat shield surrounding the unit.
  • Page 5: Manual Control

    MANUAL CONTROL There are 2 control knobs on the appliance. The right hand one controls On/Off and pilot/main burner. The left hand one is the comfort level thermostat which turns the fire down once the indicated temperature is reached. If, during use the pilot is alight but the main burner is not lit, check the thermostat position, if necessary, select a warmer setting.
  • Page 6: Slide Control

    SLIDE CONTROL 1. Press the control lever firmly to the left of its travel and listen for the spark generator clicking which should light the pilot. 2. Continue to hold down for a further 10 seconds. 3. If the pilot fails to stay alight, slide the control lever to the limit of its travel (off) & wait for 3 minutes &...
  • Page 7: Unpacking The Appliance

    UNPACKING THE APPLIANCE Carefully examine the carton for damage before unpacking. If it is obviously damaged, consult the supplier as to whether to proceed with the installation. Make sure the carton is stood upright and open the top. Remove the cardboard top fitting and place to one side;...
  • Page 8: Gas Supply

    On no account should glass mirrors, picture frames or any electrical equipment e.g. large screen TV’s be fitted or positioned on the wall above the appliance as the heat rising could damage them. This appliance is intended as a secondary heat source. Check that a primary source of heat (such as radiators) is present in the room.
  • Page 9: Site Requirements

    SITE REQUIREMENTS Cavity box Where the fire is to be fitted into any kind of enclosure, flue or false wall, heat will rise up into the void behind. This may cause shelves to overheat and where the top of the void is open (such as a flue or cavity wall) a ‘pull’...
  • Page 10 PREPARATION OF APPLIANCE AND FIXING METHOD Unpack the appliance and ensure it is correctly marked for the gas it is to be used with (see data badge). Take the appliance components and lay them out in an ordered manner. To prevent damage to the decorative frame and ceramic fire bed components (logs) place safely to one side.
  • Page 11 Method C - Fixing through the base of the fire box. Note - It is not recommended to use this method on its own as the appliance may lean forward. Use a further fixing to retain the top of the appliance. Method D –...
  • Page 12 2 – Inserted partially into a cavity wall inner leaf or opening in wall 3 – Fitted into an existing fireplace or builders opening Note - Burley Appliances do not recommend fitting into the inner leaf of timber framed buildings. A false chimney breast / deep surround or false wall should be provided Fig.
  • Page 13 7.1.4 A suitable non-combustible support platform shall be constructed within the enclosure for the appliance to sit upon if required. 7.1.5 Ensure that the wall around the opening and the base are flat and level. 7.1.6 Finally fit a non-combustible back panel against the enclosure and fit the fire surround. Due note shall be taken of the recommendations specified in section 5.
  • Page 14 7.2.1 Decide on the location of the appliance taking account of any wiring or pipe work that may be running within the wall, and mark the wall for the fire place opening to the dimensions specified in section 5b. 7.2.2 It is important to consider any precautions necessary to maintain the structural character of the wall.
  • Page 15 8.0 COMPLETE THE ASSEMBLY Fuel Bed Arrangement It is essential for clean burning that the fuel bed components are located as detailed. Do not use with broken or incorrectly fitted components. Do not use any fuel bed components other than those supplied with the product. 8.1.1 Carefully place the rear (largest) log piece on the support platform behind the burner.
  • Page 16 Fitting the Glass Panel Important - Do not use this appliance with a broken or damaged glass panel. Do not operate the appliance unless the glass panel is fitted correctly. 8.2.1 Engage the bottom edge of the glass in the groove of the front log support and within the sides of the appliance opening.
  • Page 17 With the appliance in operation, the inlet pressure must be within +/- 1.0 mbar of specification with all gas appliances in the house switched on and also with just the Burley appliance operating. If outside of tolerance the fault is most likely to be in the installation pipe work or service governor at the meter. A ‘lazy’...
  • Page 18 If you have any questions or the appliance is not operating correctly, phone the Burley help-line BEFORE you leave the installation. If the appliance is not fitted in strict accordance with these instructions, Burley cannot be held responsible for any damage caused and reserve the right to charge for any corrective work.
  • Page 19 13.0 Maintenance and Servicing 13.1 Any maintenance and servicing shall be carried out at least on an annual basis and by a competent person in accordance with relevant regulations. 13.2 Before carrying out any servicing procedure ensure the gas supply to the appliance is isolated and that the appliance is cold.
  • Page 20 Re-assemble all removed components in reverse order and carry out a commissioning procedure as detailed in the relevant section. Burley Appliances recommend the following on an annual basis. Check for combustion product leakage - It is important that the products of combustion produced by this appliance all pass through the two catalysts.
  • Page 21 Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed. Burley Appliances are the only company to bench run and thoroughly test every single Flueless gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the factory in perfect working order.
  • Page 22 1. Flue Gas Analysers – Installation & Servicing Facts • Please read this sheet even if you have fitted our fires before. • Please leave this sheet with the customer as reference for future servicing of the appliance. • Please explain to the customer how the fire operates and the details and facts listed on this sheet, particularly what the catalyst does and doesn’t do.
  • Page 23 30 years of use, the catalytic converter is as efficient as it was when brand new. Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency. (For other makes of fire please consult the relevant manufacturer).
  • Page 24 2. Gas rating of Burley Fluless Appliances Burley’s flueless gas appliances are all gas input rated in the factory and undergo further line tests for combustion, sooting and visual performance. For Installers who wish to gas input rate appliances we need to establish tolerances for pass and fail.
  • Page 25 • The appliance has been used solely in accordance with the instruction book. Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by incorrect pressure or gas type, incorrect installation, operator error, neglect or abuse.
  • Page 26 Disposal Recycling Information: The metallic & glass parts of the appliance & its packaging should be sorted for environmental-friendly recycling. WEEE: Dispose of electrical equipment in an environmentally correct manner. When disposing components containing Refractory Ceramic Fibres (RCF), we recommend that the items are not broken up, but are sealed within heavy duty polythene bags, and clearly labelled as RCF waste.
  • Page 28 Burley Magiglo fires are protected by UK patents 2193802, 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd, Lands’ End Way, Oakham, Rutland, LE15 6RB Tel: 01572 756956 Fax: 01572 724390 www.burley.co.uk Email: info@burley.co.uk...