Kipor Sinemaster IG2600 Operation Manual page 12

Digital inverter generator
Hide thumbs Also See for Sinemaster IG2600:
Table of Contents

Advertisement

1.CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete draining.
Make sure to turn the engine switch and the fuel cap
CAUTION
lever OFF before draining.
1.Loosen the cover screw and remove the left side maintenance cover.
2.Remove the oil filler cap.
3.Drain dirty oil into a container thoroughly.
4.Refill with the recommended oil, and check the oil level.
5.Reinstall the left side maintenance cover and tighten the cover screw securely.
Engine oil capacity:
0.6L
Left Side
Maintenance
Cover
Cover
Screw
Oil Filler Cap
Oil Filler Cap
Upper Level
3.Check the air cleaner.
Check the air cleaner element to be sure it is clean and in good condition.
Loosen the cover screw and remove the left side maintenance cover. Press the
latch tab on the top of the air cleaner body, remove the air cleaner cover, check the
element. Clean or replace the element if necessary.
Left Side
Maintenance
Cover
Cover
Screw
Never run the engine without the air cleaner. Rapid en-
CAUTION
gine wear will result from contaminants, such as dust
and dirt, being drawn through the carburetor, into the
engine.
Fuel Filler Cap
CAUTION
Turn the fuel cap lever to "OFF" position before transporting.
Air
Cleaner
Body
Air Cleaner Cover
Lower Tab
Air Cleaner Element
OPEN
Upper Limit Mark