Precautions For - Mitsubishi Electric FR-A740-00023 Instruction Manual

Fr-a700 series
Table of Contents

Advertisement

Adjust the output torque of the motor (current)
Parameter
Number
Zero current
152
detection level
Stall prevention
165
operation level for
restart
High-speed setting
271
maximum current
Middle-speed setting
272
minimum current
Brake opening
279
current
Current average value
557
monitor signal output
reference current
Energy saving
893
monitor reference
(motor capacity)
*1
The rated current differs according to the inverter capacity. Refer to rated specifications (page 426).
CAUTION
When Pr. 570 = "0 or 1", Pr. 260 PWM frequency automatic switchover becomes valid. (Refer to page 272.)
(2) Precautions for the FR-A740-01800 or less and FR-A740-02160 or more
If Pr. 570 is set to "0 (SLD) or 1 (LD)" when using FR-A740-01800, specifications of the inverter change to that of the
FR-A740-02160. Setting change of Pr. 570 is made valid after inverter reset and all parameter clear.
Multiple Rating
Inverter
Setting
SLD
LD
A740-01800
ND
HD
SLD
LD
A740-02160
ND
HD
For example, when using the FR-A740-01800, setting "0" in Pr. 570 and performing all parameter clear after inverter
reset will change the setting range of Pr. 9 from "0 to 500A" to "0 to 3600A" and the minimum setting increments
from "0.01A" to "0.1A". (Refer to the parameter list for other parameters.)
150
Name
0 to 120%
Setting Range
Initial Value
0 to 120%
Setting Range
Initial Value
0 to 120%
Setting Range
Initial Value
Setting Range
0 to 120%
Initial Value
0 to 220%
Setting Range
Initial Value
SLD rated
Initial Value
current
SLD value of
Initial Value
applied motor
capacity
The inverter operates in the same manner as the FR-A740-02160 or more.
Parameter setting range, minimum setting increments, initial values, etc. change to those
of the 02160 or more. Refer to the parameter list for parameters whose values change.
No change
No change
Pr. 570 Setting
0
1
0 to 150%
5%
5%
0 to 150%
110%
120%
0 to 150%
50%
50%
0 to 150%
100%
100%
0 to 220%
130%
130%
LD rated
current
*1
*1
LD value of
applied motor
capacity
*1
*1
Parameter Setting
2
3
(initial value)
0 to 220%
0 to 280%
5%
5%
0 to 220%
0 to 280%
150%
200%
0 to 220%
0 to 280%
50%
50%
0 to 220%
0 to 280%
100%
100%
0 to 220%
0 to 280%
130%
130%
ND rated
HD rated
current
current
*1
ND value of
HD value of
applied motor
applied motor
capacity
capacity
*1
Refer
to
Page
239
254
361
361
208
378
*1
267
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents