Clicking on the warning page image will take the user on to the Recovery Option Page
(Figure 92).
The recovery options available are:
Upgrade Software Image
This allows the user to reload a software image. This may be the original image if software
corruption is suspected or a step back to an old image if an incorrect image has just been
loaded.
Reset IP & Ethernet Configuration back to factory defaults
This allows the user to reset the unit back to the factory defaults:
IP Address
Netmask
Gateway
Ethernet Interface
Erase Configuration
This allows the user to erase the unit's entire configuration. Executing this option will also
erase factory settings such as target MAC address, range setting, license key, etc.
Zeroise Critical Security Parameters
This allows the user to erase the security parameters such as AES parameters.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Figure 92 - Recovery Options Page
169.254.1.1 (or 10.10.10.10)
255.255.0.0
169.254.1.0
Auto-negotiate, Auto-MDI/MDIX
154
8 Recovery Mode