Database Settings - JVC LST0728-001C Instructions Manual

Jvc network video recorder instruction manual
Table of Contents

Advertisement

Applications

Database Settings

This section enables you to specify the database settings.
Select a camera from [Main Menu]-[Camera Record Setting]-
[Device Manager], and select -[Settings...].
Memo :
● Recorded image data is referred to as the database in this
manual.
The recorded images are saved as database.
A
B
C
D
Specify the Database Settings
Item
A
Max.records
Saves recorded images to the database
until the maximum number of records is
in database
reached. Specify the maximum number of
records in the neighboring field.
If the [Archive automatically when database
is full]C check box is not selected, old
records are automatically overwritten upon
exceeding the maximum number of records.
B
Max
Saves recorded images to the database up
to the specified recording time. Specify the
timespan in
total recording time from the list in the
database
neighboring field in minutes, hours and
days.
If the [Archive automatically when database
is full]C check box is not selected, old
records are automatically overwritten upon
exceeding the recording time.
C
Archive
Starts archiving data automatically when
the database is full.
automatically
Deletes old archive data when the available
when
space of the hard disk is running low.
database is
full
110
[Camera Settings] Screen
E
Description
Item
D
In case of
For selecting the action to take when
problems are found in the database. The
database
number of options available varies depending
failure the
on whether archiving is enabled.
following
Select AArchive(no repair)B. If you have
action
selected another option, the data may be lost
syould be
if problems occur in the database.
taken
[Repair,Scan,Delete if fails]:
Two different repair methods, quick repair (recovery) and
complete repair (scan), are used. Content of the database will
be deleted if both repair methods fail.
[Repair,Delete if fails]:
The fast repair method is used. Content of the database will be
deleted if fast repair fails.
[Archive if fails]:
This option is available only if archiving is enabled for the
camera. The fast repair method is used. Content of the
database will be archived if fast repair fails.
[Delete(no repair)]:
Do not select this item.
[Archive(no repair)]:
This option is available only if archiving is enabled for the
camera. Content of the database is archived. Select this
option.
E
Datebase
Do not change the settings.
path
Memo :
● The database can store up to 600,000 records.
● The maximum database size is set to 108,000 records by
default. Do not change this setting as it may adversely affect the
recording time and recording performance.
● When archiving is used, you can store images without being
constrained by this limit.
● The following screen may appear for some settings. When it
appears, click [No].
Note :
● If you are not using a UPS, it is recommended that you select
AMax timespan in databaseB and set the time to A60minutesB.