400V class (when input power supply is 440V)
Terminal
Applicable Inverter
Screw
Type
Size
*4
FR-A740-00015 to
M4
00090-NA/N4
FR-A740-00120-NA/
M4
N4
FR-A740-00170-NA/
M4
N4
FR-A740-00230-NA
M5
FR-A740-00310-NA
M5
FR-A740-00380-NA
M6
FR-A740-00440-NA
M6
FR-A740-00570-NA
M6
FR-A740-00710-NA
M8
FR-A740-00860-NA
M8
FR-A740-01100-NA
M8
FR-A740-01440-NA
M10
FR-A740-01800-NA
M10
FR-A740-02160-NA M10-M12
FR-A740-02600-NA M10-M12
FR-A740-03250-NA M12-M10
FR-A740-03610-NA M12-M10
FR-A740-04320-NA M12-M10
FR-A740-04810-NA M12-M10
FR-A740-05470-NA M12-M10
FR-A740-06100-NA M12-M10
FR-A740-06830-NA M12-M10
FR-A740-07700-NA M12-M10
FR-A740-08660-NA M12-M10
FR-A740-09620-NA M12-M10
*1
For the 01100 or less, the cable size is that of the cable (HIV cable (600V class 2 vinyl-insulated cable) etc.) with continuous maximum permissible
temperature of 75°C (167°F). Assumes that the ambient temperature is 50°C (122°F) or less and the wiring distance is 20m (65.62feet) or less.
For the 01440 or more, the recommended cable size is that of the cable (LMFC (heat resistant flexible cross-linked polyethylene insulated cable) etc.)
with continuous maximum permissible temperature of 90°C (194°F). Assumes that the ambient temperature is 50°C (122°F) or less and wiring is
performed in an enclosure.
*2
For the 00860 or less, the recommended cable size is that of the cable (THHW cable) with continuous maximum permissible temperature of 75°C
(167°F). Assumes that the ambient temperature is 40°C (104°F) or less and the wiring distance is 20m (65.62feet) or less.
For the 01100 or more, the recommended cable size is that of the cable (THHN cable) with continuous maximum permissible temperature of 90°C
(194°F). Assumes that the ambient temperature is 40°C (104°F) or less and wiring is performed in an enclosure.
(Selection example for use mainly in the United States.)
*3
For the 00860 or less, the recommended cable size is that of the cable (PVC cable) with continuous maximum permissible temperature of 70°C (158°F).
Assumes that the ambient temperature is 40°C (104°F) or less and the wiring distance is 20m (65.62feet) or less.
For the 01100 or more, the recommended cable size is that of the cable (XLPE cable) with continuous maximum permissible temperature of 90°C
(194°F). Assumes that the ambient temperature is 40°C (104°F) or less and wiring is performed in an enclosure.
(Selection example for use mainly in Europe.)
*4
The terminal screw size indicates the terminal size for R/L1, S/L2, T/L3, U, V, W, and a screw for earthing (grounding).
For the 02160 and 02600, screw sizes are different (<R/L1, S/L2, T/L3, U, V, W, a screw for earthing (grounding)> - <P/+ for option connection>)
For the 03250 or more, screw sizes are different. (<R/L1, S/L2, T/L3, U, V, W> - <a screw for earthing (grounding)>)
The line voltage drop can be calculated by the following formula:
3 × wire resistance[mΩ/m] × wiring distance[m] × current[A]
line voltage drop [V]=
Use a larger diameter cable when the wiring distance is long or when it is desired to decrease the voltage drop (torque
reduction) in the low speed range.
CAUTION
· Tighten the terminal screw to the specified torque.
A screw that has been tighten too loosely can cause a short circuit or malfunction.
A screw that has been tighten too tightly can cause a short circuit or malfunction due to the unit breakage.
· Use crimping terminals with insulation sleeve to wire the power supply and motor.
Crimping
Tightening
Terminal
Torque
R/L1,
N·m
U, V, W
S/L2,
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
8-5
8-5
4.4
14-6
8-6
4.4
14-6
14-6
4.4
22-6
22-6
7.8
22-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
14.7
60-10
60-10
14.7
60-10
60-10
14.7
80-10
80-10
14.7
100-10 100-10
24.5
150-12 150-12
24.5
150-12 150-12
24.5
100-12 100-12 2×100
24.5
100-12 100-12 2×100
24.5
150-12 150-12 2×125
24.5
150-12 150-12 2×150
24.5
C2-200 C2-200 2×200
24.5
C2-200 C2-200 2×200
24.5
C2-250 C2-250 2×250
24.5
C2-200 C2-250 3×200
1000
Main circuit terminal specifications
Cable Sizes
2
HIV, etc. (mm
)
*1
Earth
R/L1,
U, V, W P/+, P1
(Ground)
S/L2,
Cable
T/L3
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
8
8
8
8
8
14
8
14
14
14
14
22
14
22
22
22
14
22
22
22
14
38
38
38
22
60
60
60
22
60
60
60
38
60
60
80
38
80
80
80
38
100
100
100
38
125
150
150
38
150
150
150
38
2×100 2×100
60
2×100 2×125
60
2×125 2×125
60
2×150 2×150
100
2×200 2×200
100
2×200 2×200
100
2×250 2×250
100
2×250 3×200 2×100 2×500 2×500 2×240 2×240 2×120
AWG/MCM
*2
PVC, etc. (mm
R/L1,
R/L1,
U, V, W
U, V, W
S/L2,
S/L2,
T/L3
T/L3
14
14
2.5
2.5
12
14
2.5
2.5
12
12
4
4
10
10
6
6
8
8
10
10
6
8
16
10
6
6
16
16
4
4
25
25
4
4
25
25
1
2
50
50
1/0
1/0
50
50
1/0
1/0
50
50
3/0
3/0
50
50
3/0
3/0
70
70
4/0
4/0
95
95
250
250
120
120
300
300
150
150
2×4/0 2×4/0 2×95
2×95
2×4/0 2×4/0 2×95
2×95
2×250 2×250 2×120 2×120
2×300 2×300 2×150 2×150
2×350 2×350 2×185 2×185
2×400 2×400 2×185 2×185
2×500 2×500 2×240 2×240 2×120
2
)
*3
Earth
(Ground)
Cable
2.5
4
4
10
10
16
16
16
16
25
25
25
25
35
50
70
95
95
95
120
150
2×95
2×95
2
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Table of Contents