1N120 Wiring Diagram
1. Terminal block
2. Thermostat with reset
3. Reed sensor
4. Switches with lights
5. Relay
6. Heating elements
7. Thermostat
L
N
E
1
10. operatIoN
• Select power level using switches on front of unit. The two
switches give 4 levels (including off). in Uk conditions the
unit should normally be switched to full power.
• Switch on electrical supply.
• Turn on tap. when the flow rate exceeds about 1.2 litres
per minute the unit will start to heat the water.
• as the flow rate is increased the temperature will start
to fall.
• if the flow rate is gradually reduced the temperature will
rise gain. if the temperature exceeds approximately
60 degrees the unit will switch off to prevent scalding.
it will restart again when the unit has cooled provided the
flow is maintained.
do Not fIt a tHerMostatIc MIxINg ValVe
WItH tHe INlINe. UNpredIctable
perforMaNce WIll resUlt.
If a tap Is closed brIefly aNd tHeN
SwiTChEd baCk ON aGaiN, SUPPliEd
Water May be teMporarIly be Very Hot
dUe to retaINed eNergy WItHIN tHe
HeatINg eleMeNt beINg traNsferred to
a sMall VolUMe of Water.
do Not sWItcH oN If tHere Is aNy
possIbIlIty tHat tHe pIpeWorK coUld
be frozeN.
11. MaINteNaNce
• To clean, switch power off and wipe with a damp cloth.
do not use abrasive materials as this may cause
permanent scratches.
NeVer alloW Water to coMe INto
coNtact WItH electrIcal parts.
Note tHat tHe coNseqUeNces of
lIMescale are exclUded froM tHe
WarraNty.
p.N. 166018
3
7
R
2
3
4
5
12. WarraNty
hyco manufacturing ltd will in its sole discretion repair or
replace any defective product arising within a period of one
year from the date of purchase, provided that:
• it has been used in accordance with these instructions.
• Failures are not the result of limescale, misuse or
vandalism.
in the event of a failure please call our technical department
on 01977 517555 before taking further action.
Please note that we would normally send spares or arrange
collection and return of the unit for repair. we are generally
unable to perform repairs on site. we will use reasonable
endeavors to effect a repair within an acceptable period, but
6
we cannot guarantee to meet any specific timescale.

13. troUble sHootINg

symptom
No water from tap
water temperature
too cold
(Consult Performance
Chart in Section 5.)
water temperature
too high
water dripping from
relief valve
alWays sWItcH poWer off before
UNdertaKINg MaINteNaNce.
Cause
No water supply.
Excess flow rate
Simultaneous use
of multiple outlets
Thermostat has
tripped due to low
flow rate
Too much power
insufficient flow
Excess water
pressure
hyco manufacturing ltd
Tel: 01977 517555 Fax: 01977 517666
web: www.hyco.co.uk
E-mail: sales@hyco.co.uk
solution
Switch on if
necessary
reduce flow, fit
sprayhead taps.
restrict use to one
outlet at a time
Thermostat will
reset itself. increase
flow.
reduce power level
using switches on
front of unit
increase flow rate
Fit 3 bar pressure
reducing valve (hyco
PrV30T or similar)
California drive
whitwood
Castleford
west Yorkshire