  • Page 1 Product Instruction Manual IN44T & IN60T Instantaneous inline water heater Version 3.2 Jan 2015 V15.6/3...
  • Page 3: Important Safety Points

    Thank you for purchasing a Hyco instantaneous water heater. Instantaneous water heaters are very energy efficient since they only consume energy when they are used and so have no standing losses. The IN44T & IN60T models are mains pressure instantaneous water heaters with external electronic temperature control.
  • Page 4: Installation

    2. Installation Wall Mounting Do not install if there is a risk of water freezing in the heater. Do not install the heater where the consequences of a leak could be unusually severe. (e.g. above computer equipment). • When choosing a location for the heater, consider the visibility of any leak that might arise.
  • Page 5 There are two options available for the mounting of the product, select either the key hole slots at the rear of the product or use the supplied bracket. THERMAL CUT OUT Using the bracket Using the supplied bracket and ensuring a level, mark the two screw holes onto the desired mounting surface.
  • Page 6 Plumbing connections The heater is designed for use with spray head type taps. Ensure the following criteria are met for the water supply: • Minimum flow = 2.0L/min • Pressure Min/Max = 0.1Mpa/0.75Mpa • Water resistivity = ≥1300 Ωcm Suitable for use with pre-heated water e.g. solar heating systems to a maximum of 60 Flush supply pipes to remove any debris before connecting the heater to the water supply.
  • Page 7 Electrical connection Do not commence electrical installation before connecting the heater to the water supply and verifying there are no leaks or air gaps. Electrical installation must be carried out by a qualified electrician in accordance with the latest edition of the IEE wiring regulations. •...
  • Page 8: Operation

    3. Operation Once installed and connected to the electrical supply the heater is ready for use. Turn on the heater using the power On/Off button. On first installation the temperature setting will default to 38 C. To adjust this press the +/- buttons until the desired maximum target temperature is displayed.
  • Page 9: Maintenance

    4. Maintenance • Always disconnect the power before commencing any cleaning or maintenance. • Never open the cover of the heater without first isolating the mains power supply. To clean the heater cover only use a clean damp cloth, do not use abrasive compounds. Electrical and plumbing components should be inspected on a regular basis by a suitably qualified/competent person.
  • Page 10: Specifications

    5. Specifications IN44T IN60T Power supply 230V~ 50Hz 230V~ 50Hz Dimensions H140 x W190 x D80mm H140 x W190 x D80mm Power 4400W 6000W Protection class IPX4 IPX4 Rated current Over heat protection temperature Minimum operating 2.0L/Min 2.0L/Min flow rate Minimum operating 0.1MPa 0.1MPa...
  • Page 11: Troubleshooting

    This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion replace, repair or refund any faulty unit. Incorrect installation and failure to follow correct operating instructions are excluded.
  • Page 12 In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed out dustbin. Hyco Manufacturing Ltd Normandy Court Express Way...