and 11 in the 15 pin plug. If the meter reads zero the
lock switch or the wiring to the lock switch is
defective. If the meter reads infinity go to step 2.
2, Depress the arm of the lock switch, and measure
the resistance between pins 10 and 11 in the 15 pin
plug. If the meter reads infinity the lock switch or
the wiring to the lock switch is defective. If the meter
reads zero the control is defective.
Door latch is partly closed with door open, cannot close
door:
1. Program the oven for self-clean, and hold in on the
door switch for 30 seconds. Touch cancel and hold
door switch in for 30 seconds. The lock motor should
lock and unlock the door.
71