5.2 Operation Mode Table
FIP-1.N1 When Power is Turned On
Step
Possible causative parts:
PHD ASSY (PL4.1.21)
FUSER ASSY (PL6.1.1)
TRANSFER ASSY (PL6.1.7)
DRIVE ASSY SUB (PL7.1.1)
DRIVE ASSY MAIN (PL7.1.2)
Checking the Main Motor
Does the noise arise from the printer?
1
Checked by [Digital Output] - [DO-0] in [CE Diag] tab of [CE
Diag].
Checking after reseating the PHD ASSY
Reseat the PHD ASSY.
2
Does the noise arise from the printer?
Checked by [Digital Output] - [DO-0] in [CE Diag] tab of [CE
Diag].
Checking after reseating the TRANSFER ASSY
Reseat the TRANSFER ASSY.
3
Does the noise arise from the printer?
Checked by [Digital Output] - [DO-0] in [CE Diag] tab of [CE
Diag].
Checking after reseating the DRIVE ASSY MAIN
Reseat the DRIVE ASSY MAIN.
4
Does the noise arise from the printer?
Checked by [Digital Output] - [DO-0] in [CE Diag] tab of [CE
Diag].
Checking the Sub Motor
Does the noise arise from the printer?
5
Checked by [Digital Output] - [DO-7] in [CE Diag] tab of [CE
Diag].
Checking after reseating the PHD ASSY
Reseat the PHD ASSY.
6
Does the noise arise from the printer?
Checked by [Digital Output] - [DO-7] in [CE Diag] tab of [CE
Diag].
Checking after reseating the FUSER ASSY
Reseat the FUSER ASSY.
Warning: Start the operation after the FUSER ASSY has
7
cooled down.
Does the noise arise from the printer?
Checked by [Digital Output] - [DO-7] in [CE Diag] tab of [CE
Diag].
Check
1 - 368
Chapter 1 Troubleshooting
Remedy
Yes
Go to step 2.
Go to step 5.
Go to step 3.
End of work.
Go to step 4.
End of work.
Try replacing the
PHD ASSY (refer
to Removal 4/
Replacement 50),
TRANSFER
ASSY (refer to
Removal 21/
End of work.
Replacement 33)
and DRIVE ASSY
MAIN (refer to
Removal 32/
Replacement 22)
one after another.
Check the
Go to step 6.
installation
situation of printer.
Go to step 7.
End of work.
Go to step 8.
End of work.
No