Calling Number

Programs Used: 321 and 322
When calls are made using ISDN services, the telephone number for which the call originates must be
identified to the PSTN.
1. Complete the
Record Sheets"
2. From the Program Menu, click
Trunk > ISDN > Calling Number.
The ISDN Calling Number
Identification screen displays
(shown right).
3. Enter the OLG Number, or click the
List button to view a summary list
of programmed OLGs.
4. Enter Program 321 data.
5. Enter Program 322 data.
6. Click Submit.

321 Calling Number Identification

Prerequisite Program:
The Calling Number ID is what is defined as the user supplied Calling Number. This number may be
optionally screened by the PSTN to ensure only calls from valid billable telephone numbers are allowed to
originate calls.
F
IELD
OLG Number
01 Default Number
02 Number Prefix
03 Number
Verification
04 Default Number 2
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
"Calling Number
on
page
D-33.
306
on page 6-4
D
ESCRIPTION
Enter the OLG Number.
Possible values: 1~32 (CTX100), 1~50 (CTX670 Basic), 1~128 (CTX670 Exp),
Enter the telephone number to use by default when originating a call. This is the
number that the PSTN has registered for billing purposes.
Possible values: Up to 10 ASCII characters (default = no value)
Enter the prefix telephone number for which a DID number will be appended to
create a User Identified telephone number.
Possible values: Up to 10 ASCII characters (default = no value)
This number may or may not be a billed number, but is used for Caller ID at the
distant end and could be used for returning your call.
Specify whether the number provided should be screened by the PSTN before the
call is to proceed.
Possible values: Enable or Disable (default)
Enter the second telephone number to use by default when originating a call.
Possible values: Up to 10 ASCII characters (default = no value)
This is the number that the PSTN has registered for billing purposes. The second
number is for BRI only
(default = no value)