Transfer Hsp Over A Network Connection - GE D20MX Instruction Manual

Hide thumbs Also See for D20MX:
Table of Contents

Advertisement

Transfer HSP over a network connection

74
For Password: type the password and press Enter.
Result: The D20M> prompt appears.
4.
Optional: Speed-up communications to shorten download time
Type Baud 115200 and press Enter.
Select 57600 or 38400 if communications errors have occurred previously. Such errors
can occur due to the presence of ambient EMI, a long cable length, a PC with
communication limitations due to CPU speed or when using some serial to USB
adapters.
Result: The D20MX is now communicating at 115,200 baud.
4.1.
Select Setup > Serial port...
Result: Tera Term: Serial port setup dialog appears.
4.2.
Select 115,200 from the Baud Rate drop-down list.
4.3.
Click OK.
Result: TeraTerm main window appears and is communicating at 115,200
baud.
5.
Transfer the HSP file:
5.1.
Press Enter to verify that communication is active.
Result: The D20M> prompt appears if the connection is active.
5.2.
Type rz and press Enter to put the D20MX into the state where it is ready to
receive the downloadable code file
5.3.
Click File > Transfer > ZMODEM > Send from menu bar.
Result: A dialog box opens, prompting you to locate the hsp.tar file that you
wish to download.
5.4.
Select the hsp.tar file from the folder created in step 4 of "Stage HSP File for
Serial Transfer", and click Open to start the transfer.
Do not press any keys on keyboard and do not move the TeraTerm window
during download.
Result: The file transfer may take from less than 10 to over 30 minutes, depending on
communication speed selected. When complete, the D20M> prompt appears.
6.
Optional: If you had changed the baud rate prior to the transfer, change the baud rate
back to the original baud rate.
If the original baud rate was 9600, type Baud 9600 and press Enter.
If the original baud rate was 19200, type Baud 19200 and press Enter.
Result: The D20MX is now communicating at 9600 or 19200 baud.
6.1.
Select Setup > Serial port...
Result: TeraTerm: Serial port setup dialog appears.
6.2.
Select 9600 or 19200 from the Baud Rate drop-down list.
6.3.
Click OK.
Result: TeraTerm main window appears and is communicating at 9600 or
19200 baud.
7.
Close the TeraTerm window.
To transfer an HSP file to the D20MX over a network connection:
1.
Start SGConfig.
Result: The Welcome to SGConfig screen appears.
CHAPTER 5: CONFIGURING THE SOFTWARE