Page 1
Natural Gas L.P.G. Serial No: MODEL: MB055 MB105 MB155 MB185 MB265 MB405 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapours and liquids in the vicinity this or any other appliance.
GENERAL SPECIFICATIONS WATER CONTENT Litre Model Model Model (gal) (0.18) (0.3) (0.4) Model Model Model (0.4) (0.4) (0.5) MAXIMUM WATER PRESSURE 8 bar (125 psi) MAXIMUM WATER FLOW TEMP 45.0 °C 110 (°F) ELECTRICAL SUPPLY 230V 50Hz, FUSED AT 3A. POWER 100W PERFORMANCE SPECIFICATIONS - NATURAL GAS GAS CATEGORY, TYPE AND SUPPLY PRESSURE G20 @ 20 mbar (8 in.
PART ONE - USER'S OPERATING INSTRUCTIONS FOR YOUR SAFETY - READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. SECTION 1 / START-UP PROCEDURES BEFORE START-UP BURNERS Clean air louvres of dust, lint and debris.
FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Isolate the appliance with the Service Cock inside. If This appliance is equipped with an ignition device this is not accessible, isolate at the gas meter.
OPERATING MODELS 185, 265 and 405 Quick Start Pool Filter Blocked - Yellow Check that the Electricity and Gas Supplies are On - If the pump is running and there is on. Turn on the Pool Pump. Turn on the Heater insufficient pressure, possibly due to a with the switch on the Front Panel and set the blocked Pool Filter.
AFTER START-UP SECTION 2 / CAUTION Feel the inlet and outlet pipes. Outlet pipe should be Elevated water temperature can be hazardous, and only slightly warmer than the inlet. It should not be the U. S. Consumer Product Safety Commission hot.
3. Make visual check of the burner and pilot COLD WEATHER OPERATION flame. Flame pattern on the main burner and pilot is indicated in the previous illustration. Yellow MODERATE CLIMATE: Heater operation can con- flame means restriction of the air openings. Lifting tinue during short term cold spells.
PART TWO - INSTALLATION/SERVICE INSTRUCTION SECTION 1 / RECEIVING EQUIPMENT WARNING: This appliance must be installed and serviced by a CORGI registered installer. On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the delivery note when signing for equipment.
SECTION 2 / INSTALLATION Models 185, 265 & 405 BS. 6891; Installation of low pressure pipework. INSTRUCTIONS BS. 6644; Installation of Gas Fired Hot Water Boilers 60kW to 2MW. IMPORTANT NOTICE CP 341; Water Supply. British Gas Publications: IM2; Purging Procedures on Non-domestic These instructions are intended for the use of quali- Gas Installations.
Page 11
CLEARANCES For servicing, provide at least 600mm (24") in front of the heater for burner tray removal, and at least ALL HEATERS 450mm (18") on water connection side of the heater For clearances from combustible surfaces, see the to inspect and delime the heat exchanger. chart below.
OUTDOOR HEATERS 105 & 155 Models FLUE TERMINAL (Outdoor) Stackless Top Illustra- These heaters are certified by Advantica for outdoor tion installation, when equipped with the approved tops designated for outdoor use. Top Vent Opening WARNING: The heater shall not be located in an area where water sprinklers, or other devices, may cause water to spray through the cabinet louvres and into the heater.
INDOOR HEATER 185, 265 & 405 Models FLUE TERMINAL (Indoor) Draught Diverter The design is also certified by Advantica for indoor Illustration installation when fitted with the appropriate draught diverter and a suitable flue system to outside. Note 1. Remove the louvred jacket top by removing that the heater must be in a room separated from four (4) No.10 flat head screws.
Page 14
SPECIFICATIONS & DIMENSIONS 055 - 105 - 155 MODEL FLUE DIA CONNECTIONS SHIPPING WEIGHT WATER kg (lbs) mm (in.) APPLIANCE DIVERTER 100 (4) ½" 1½" NPT 31.8 (70) 2.3 (5) 127 (5) ½" 1½" NPT (105) 3.5 (8) 152 (6) ¾"...
VENTILATION REQUIREMENTS The flue/chimney design should avoid the formation of excessive quantities of condensate and for this The heater must have both ventilation and reason it is recommended that all chimneys are combustion air. Safe and efficient operation of the suitably insulated and lined.
GAS SUPPLY CONNECTIONS Honeywell Gas Valve Gas piping must have a manual shut-off valve located Burner Pressure outside the heater jacket. All gas piping should be adjustment tested after installation in accordance with local codes. CAUTION: The heater and its manual shut off valve must be disconnected from the gas supply during any pressure testing of that system at test pressures in excess of 150mbar (2.2psi).
PLUMBING FOR WATER CONNECTIONS LEFT SIDE WATER CONNECTION CONVERSION 185, 265 & 405 Models Only There are two ways of achieving the connection conversion. Removal and turning of the heat exchanger or, swapping of the headers. Generally swapping headers is easier and this process is described here. 1.
Page 19
This page is intentionally left blank 30-09-04...
CONNECTIONS 2" CPVC Adapters All Models LOCATION The heater requires water flow and pressure to operate properly. It must therefore be installed downstream of the discharge side of the filter and pump. A typical installation is plumbed as follows: 1. The Pump outlet is plumbed to the inlet of the Filter. mbsmall.tif 2.
Page 21
055 Models Only 185, 265 & 405 Models Only 055hdr.tif Ensure the O rings are properly seated before tightening hand tight. They maybe lubricated with silicone grease. Glue plastic pipe directly in to the 105 Model Only unions. The 105 accepts direct connection to 1½"...
EXTERNAL AUXILIARY BYPASS VALVE The Electronic Ignition Device automatically lights (Where Required) the pilot and main burners upon a call for the heat. The heater is supplied with a transformer for 230V An auxiliary bypass valve should be used when flow mains input.
SECTION 3 / SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS 055 MODEL Manual High Limit Reset Button 105 MODEL Pressure Switch Burners & Pilot Drain Valve Unitherm Governor Gas Valve (Bronze Units Only) Bypass Valve Solid State Thermostat & High Limits Ignition Control &...
Page 26
GENERAL LOCATION OF CONTROLS - continued. 185-265-405 MODEL 155 Model 185,265 & 405 Models CONTROL PANEL REMOVAL CONTROL PANEL REMOVAL 1. Remove lower door. 1. Remove (4) screws from sides of control 2. Remove (2) screws from bottom flange of panel.
185 265 and 405 Models Pool Filter Blocked - Yellow On - If the pump is running and there is insufficient pressure, possibly due to a blocked Pool Filter. The Heater will not run. On/Off Overheat - Red Switch On - This indicates the Heater has overheated and shutdown.
Page 28
All Models FLAME ROLL-OUT SAFETY SWITCH PRESSURE SWITCH ADJUSTMENT 1. With pump and heater on, turn adjustment knob (clockwise) until a click is heard from the gas valve. 2. Turn adjustment knob (counter clockwise) rollout.tif 1/4 turn. 3. Turn pump off and on several times. The heater is equipped with a thermal cutoff device to Heater should shut off immediately.
3. To remove the manual reset high limit, follow the 055, 105 & 155 Models procedure for the high limit thermostat but in GAS VALVE REMOVAL addition, disconnect the electrical connections and release its mounting bracket from the side 1. Remove burner tray. (See burner drawer panel by removing the M4 nut at the front of the removal procedure).
185, 265 & 405 Models All Models PILOT REMOVAL AND CLEANING CONTROL IMMERSION WELL REPLACEMENT 1. Disconnect pilot tubing, and wires from 1. Shut water off to heater and drain heat gas valve. exchanger. 2. Remove pilot assembly from burner tray. 2.
All Models To test the operation of the Unitherm Governor, place in hot water (over 43°C) and watch for movement DESOOTING PROCEDURE against spring. If there is no movement, replace unit. CAUTION: SOOT IS COMBUSTIBLE. EXERCISE EXTREME CARE. NEVER USE A WIRE BRUSH. 055, 105 &...
SECTION 4 / TROUBLE SHOOTING GUIDE These instructions are primarily intended for the use of qualified personnel specifically IMPORTANT NOTICE: trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel must be Corgi Registered. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.
Page 33
PROBLEM CAUSE SOLUTION Pilot outage. Low gas pressure..... Adjust gas pressure. Restricted pilot......Clean pilot. Weak pilot generator....Replace pilot. Faulty Detection Electrode or PCB Yellow lazy flame Low gas pressure...... Adjust gas pressure. *Insects or debris clogging burner intake ports.....Clean burners. Inner &...
Page 34
055, 105 & 155 Models WARNING ELECTRICAL TROUBLESHOOTING HIGH VOLTAGE For qualified Technicians ONLY NOTE: This heater is equipped with an ignition module that shuts off pilot gas if pilot START fails to light after the third attempt. This is identified by the green LED flashing on the ignition module.
Page 35
ELECTRICAL TROUBLESHOOTING 055, 105 & 155 Models If the pool/spa water is too cold, troubleshoot the system as follows: Check voltage at 24 V terminals. VOLTAGE BETWEEN 21.5-28.5 V. VOLTAGE OUTSIDE RANGE 21.5-28.5 V. Set control to max. temperature. After 2-3 Check transformer, 230 V supply, correct as necessary.If 230 V side of transformer is open circuit, check cycles, check water temperature.
Page 36
185, 265 & 405 Models Logs CONTROL FAULT DIAGNOSIS The Control keeps a log of the number of times the Pressure Switch, Manual Overheat, Hi-Limit Before commencing a diagnosis it is recommended and Thermal Fuse (Rollout) fail. These can be that you familiarise yourself with the functions of the examined and reset to zero in Setup Mode.
Page 37
Setting Pool Temperature Lock/Unlock On / Off Postion Temperature Display Button Switch Setting Knob Setting Factory Setting Alternative Display Indicator Display units ° F = Fahrenheit ° C = Centigrade ° F or ° C Maximum temperature 32 °C (90 °F) 41 °C ( 106 °F) PL or SPA Filter Pressure Log...
SECTION 5 REPLACEMENT PARTS LIST 055 & Easiheat Model NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. spares2.pcx Pilot ( Silver ) Pilot ( Black ) europilot.tif softlite.tif inject.tif...
Page 39
Description - 055 Model Part Code BURNER TRAY Burner Tray w/Gas Valve Natural Burner Tray w/Gas Valve Propane Burner 301210 Burner Injector Natural No.50 350079 Burner Injector Propane No.57 350083 CONTROLS High Limit 57ºC (135ºF) 600889B High Limit Manual Reset 102ºC M3029 Thermostat Control (Solid State) 600960...
REPLACEMENT PARTS LIST 105 Model 16-H softlite.tif 11-H 14-H 12-H 10-M Pilot (Silver) inject.tif spares105_2.tif Pilot (Black) 10-12-01 europilot.tif...