Wiper (SCU-2370/VAC/VAC1)
You can use Wiper to wipe out the front glass of the housing so as
to secure a clear view.
To activate Wiper, set the menus below to your preference.
Pump Enable:
Activate or deactivate the pump function.
-
On: Activate the pump function that is connected to the
wiper. Creates detailed submenu items related to the
Pump function.
-
Off: Deactivate the pump function that is connected to the
wiper.
With Enable On, the Aux output function in Alarm Setting will be
disabled.
If "Enable" is set to On, you can operate the wiper using the
command of "AUX1 On".
Wiper :
Activate or deactivate the wiper function.
Preset :
Select a Preset run with Wiper function.
Set the preset to face the pump's water outlet.
Pump Delay :
Operating time of the pump. (1 ~ 30 seconds)
Duration :
Operating time of the pump and wiper. (6 ~ 30 seconds)
If the pump is turned off, means operating time of the wiper.
Delay Off :
Operating time of the wiper. (6 ~ 30 seconds)
Pump Delay
: Pumps water
towards the
housing's front
glass.
(Wiper & Pump Operation)
Duration
: Wiper clears the
housing during the
pumping.
Main Menu
P/T Setting
Wiper
Wiper
Delay Off
: Wiper clears out
remaining water.
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
Pan Limit
Tilt Limit
Area Setting
Area Masking
Housing Load
03 KG
Wiper
Prop. P/T
ON
Image Hold
OFF
Pump Enable
OFF
Wiper
OFF
Duration
06 SEC
Pump Enable
ON
Wiper
OFF
Preset
001
Pump Delay
03 SEC
Duration
06 SEC
Delay Off
06 SEC