IDENTIFICATION OF CONTROLS
REAR PANEL
14 IR IN/OUT: These mini-jacks accept and output remote-controlled
codes in electrical format, using industry-standard protocols, for use
with 'IR-repeater' and multi-room systems and related technologies.
IR IN: This input is connected to the output of an IR (infrared) repeater
(Xantech or similar) or the IR output of another component to allow
control of the C 37SBEE from a remote location.
IR OUT: When connected to the IR IN of an ancillary equipment, direct
the ancillary equipment's own remote control to the C 37SBEE's infrared
receiver to command or control the linked unit.
All NAD products with IR IN/IR OUT features are fully compatible with
the C 37SBEE. For non-NAD models, please check with your other
product's service specialists as to their compatibility with the C 37SBEE's
IR features.
15 +1 2V TRIGGER OUT: The +12VTRIGGER OUT is used for controlling
external eqUipment that is equipped with a +12Vtrigger input. This output
will be 12Vwhen the C37SBEE is ON and OVwhen the unit is either OFF or
in standby. This output can drive a load up to SOmA at 12V
16 R5-232: Connect thiS interface via RS-232 serial cable (not supplied) to any
Windows· compatible PC to allow remote control of the C37SBEE through
NAD's proprietary PC software or other compatible external controllers.
NAD is acertified partner of MAX and Crestron and fully supports these
external devices. See your NAD audio specialist for more information.
17 Me INPUT: Input for a Moving Coil phono cartridge. Connect the twin
RCA lead from your turntable to this input if you are using a Moving
Coil cartridge.
18 MC-MM SWITCH: Slide this switch to either MM (MOVing Magnet) or
MC (Moving Coil) depending upon the phono cartridge being used.
19 PHONO GROUND CONNECTOR: Turntables normally includes a single
wire earth lead. Use the C 37SBEE phono ground connector to connect
this lead. Unscrew the terminal to expose the hole, which will accept
the lead. After insertion, tighten the terminal to secure the lead.
20 MM INPUT: Input for a Moving Magnet phono cartridge. Connect
the twin RCA lead from your turntable to this input if you are using a
Moving Magnet cartridge.
21 SPEAKERS A, B: The C375BEE is equipped with two sets of speaker
connectors. Use the Speakers A terminals for the "main" speakers and
use the Speakers Bterminals for a second pair, for example, extension
speakers located in another room.
Connect the right speaker to the terminals marked"R +" and "R-"
ensuring that the"R+"is connected to the "+"terminal on your
loudspeaker and the "R-" is connected to the loudspeaker's '-"terminal.
Connect the terminals marked "I.+"and "L-"
to
the left speaker in the
same way.
In Bridge Mode, connect the single speaker to the terminals marked
"R
+"
and "L+"ensuring that the"L+"is connected to the"+" terminal
on your loudspeaker and the "R+" is connected to the loudspeaker's "-"
terminal. Refer also to the section above about "BRIDGE
MODE~
Always use heavy duty (16 gauge; l.5mm, or thicker) stranded wire to
connect loudspeakers to your C 375BEE. The high-current binding post
terminals can be used as a screw terminal for cables terminating in
spade or pin sockets or for cables with bare wire ends.
10
22 AC MAINS INPUT: The C375BEE comes supplied with a separate AC Mains
cable. Before connecting the cable to a live wall socket, ensure that it is
firmly connected to the C375BEE's AC Mains input socket first. Connect
only to the prescribed AC Outlet, i.e., 120V 60 Hz or 230V 50 Hz. Always
disconnect the AC Mains cable plug from the live wall socket first, before
disconnecting the cable from the C375BEE's Mains input socket.
23 POWER SWITCH: The POWER switch supplies the master AC mains
power for the C 375BEE. When this switch is at ON position, the
C 375BEE is in standby mode as shown by the amber status condition
of the standby LED. Toggle the front panel's STANDBY button to switch
ON the C375BEE or back to standby mode. If you intend not to use the
C375BEE for long periods of time (such as when on vacation), switch
the POWER switch to the OFF position. When the POWER switch is at
OFF position, the front panel power button or SR Bremote control
cannot activate the C 375BEE.
24 SWITCHED AC OUTLET (120V version only): This convenience outlet
can supply switched power to another component or accessory. With
the Power switch at the rear panel set to ON position, this outlet is
powered ON or OFF by the front panel STANDBY switch or by the SR 8's
[ON/OFF] buttons. The total draw of all devices connected to this outlet
must not exceed 100 watts.
25 FUSE HOLDER: In the unlikely event a fuse may need to be replaced,
unplug the AC cord from the wall. Then, remove all connections from
the amplifier. Use a fiathead screw driver or similar to open the fuse
holder via the slot indicated. With the screw driver in place, push and
turn counterclockwise to open the fuse holder. Only replace the
fuse with the same type, size, and specification - T1 OAL 250V for 120V
version or T5AL 250V for 230V version.
IMPORTANT NOTICE
Do not use any substitute fuses ofdifferent types or with different ratings
or values. Failure to observe this precaution may cause damage to the
amplifier circuits and may create a fire hazard and/or defeat the safety
built into the C 375BEE and may void the warranty.