4-24 Configuring Your Server
Server
The Server menu appears if you move the cursor to "Server".
See the table below for the items.
Option
Assert NMI on
SERR
Post Error Pause
AC LINK
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK".
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown*
* Press the POWER/SLEEP switch continuously for four seconds or longer. This forcibly turns off
the power. After this operation, the system does not turn on the power even though the AC-LINK
setting is set to Power On.
IMPORTANT:
To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC Link] - [Power On].
If the server is connected to the UPS, set at least 10 seconds delay in
the power-on schedule.
Parameter
Description
Disabled
Indicates whether PCI SERR is
[Enabled]
supported or not.
Disabled
Indicates whether POST is aborted once
[Enabled]
at the end of POST if an error occurs
during the execution of POST.
Stay Off
Specify the state of power when the AC
[Last State]
power to the server is turned off once
Power On
and then on. (See the table below.)
Setting of AC LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
Off