Master Spas LSI 557 Owner's Manual
Master Spas LSI 557 Owner's Manual

Master Spas LSI 557 Owner's Manual

Master spas portable spa owner's manual
Hide thumbs Also See for LSI 557:

Advertisement

MASTER SPAS OWNER'S MANUAL
Welcome To Ultimate Relaxation!
Thank you for choosing your new spa built by Master Spas. Please read the
entire Owner's Manual before installing and using your spa. The goal of this
manual is to provide you with safety and operational information plus some tips
that will help you enjoy your spa to its fullest.
At the time of print, this manual is accurate in its information. Master Spas
reserves the right to change or improve its product without prior notice.
To check on updates or for other information, please visit www.masterspas.com
and follow the links to the customer service section.
Record Of Ownership
Name _____________________________________________________
Address ____________________________________________________
City _____________________________ State ______ Zip ___________
Date Purchased ______ /______ /_______
Model ________________________ Serial #______________________
Dealer Name _______________________________________________
Phone # (______)________-__________
Service Tech Rep_____________________________________________
*Serial Number Location
The serial number for your spa is located in the filter area, on the spa system
pack, or on the UL plate on the skirting. It will start with "M" followed
by a 6-digit number.
America's Leader In Luxury
Ex. M404590
6927 Lincoln Parkway
Fort Wayne, Indiana 46804
260-436-9100
www.masterspas.com
1
M A S T E R
S P A S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LSI 557 and is the answer not in the manual?

Questions and answers

Summary of Contents for Master Spas LSI 557

  • Page 1 MASTER SPAS OWNER’S MANUAL Welcome To Ultimate Relaxation! Thank you for choosing your new spa built by Master Spas. Please read the entire Owner’s Manual before installing and using your spa. The goal of this manual is to provide you with safety and operational information plus some tips that will help you enjoy your spa to its fullest.
  • Page 2: Table Of Contents

    Wiring Schematic ................13 120/240 Volt Systems ..............14-15 Site Preparation ................16-17 Installation Instructions..............18-19 Water Chemistry Terms ..............20-21 Spa Water Maintenance - Master Spas and Down East Spas ECO PUR ™ Information ..............22 Water Quality Maintenance Start-Up ............23 Advantages of ECO PUR ™...
  • Page 3: All Spa Models, Personal Safety

    Introduction It’s time to relax! You now have your very own portable spa by Master Spas, Inc. By fully understanding the operation of each of the features of your new Master Spa you will be assured of many years of hassle-free, hot water therapy and fun.
  • Page 4: Read And Follow All Instructions

    SAFETY INSTRUCTIONS Important Safety Instructions When installing and using this electrical equipment, basic safety precautions should be observed including the following: Read And Follow ALL INSTRUCTIONS 1. WARNING. To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
  • Page 5 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) 8. WARNING - TO REDUCE THE RISK OF INJURY: Always enter and exit a spa slowly. Do not use the spa alone. Before entering the spa, always measure the water temperature with an accurate thermometer.Tolerance of water temperature regulating devices can vary as much as plus/minus 5°...
  • Page 6 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) People with infections, sores or the like should not use the spa.Warm and hot water temperatures may allow the growth of infectious bacteria if not properly disinfected. 10. DANGER - RISK OF ELECTRIC SHOCK. Do not permit any electric appliance, such as a light, telephone, radio or television, within five (5) feet of the spa.
  • Page 7: Glossary Of Spa Terminology

    GLOSSARY OF SPA TERMINOLOGY 1. NECK JETS Your new Master Spa features a variety of jet styles. All jets, regardless of style return the water to the spa. Air is mixed with the water 2. SHOULDER JETS by using the air controls creating a gentle to most vigorous massage.
  • Page 8 GLOSSARY OF SPA TERMINOLOGY 6. CASCADE WATERFALL VALVE - Located on the topside of the spa, this valve adjusts water flow to the cascade waterfall.This feature is available in the LS Series only. Cascade Waterfall Valve 7. AIR CONTROL VALVES - These are located around the top of your spa.
  • Page 9 GLOSSARY OF SPA TERMINOLOGY 9. PERSONAL REMOTE CONTROL - The Legend Series (LS) spas have additional remotes which allow the user to control the jet therapy while remaining in his/her seat. By pressing the control one time, you will activate low speed.
  • Page 10 GLOSSARY OF SPA TERMINOLOGY 13. FILTER LID -Your filter lid will serve to prevent major objects from entering your filter area and possibly damaging your filter elements which are located under the filter lid.These filter elements are designed to remove small debris and oils from your spa water.
  • Page 11 (if applicable). It will deactivate when any other control function is manually activated and will reactivate after one hour of inactivity.The ozonator is standard on all Master Spas and optional on all Down East and Freedom Spas.
  • Page 12: Electrical Installation Requirements

    All Master Spas equipment packs are wired for 240 VAC only. The only electrical supply for your spa must include a 50 AMP switch or circuit breaker to open all non-grounded supply conductors to comply with section 422-20 of the National Electrical Code.The disconnect must be readily accessible to the spa occupants, but...
  • Page 13: Wiring Schematic

    WIRING SCHEMATIC - 240 VOLT SPA HOOK-UP * Actual wiring of GFCI will vary by manufacturer of GFCI.The GFCI shown is a Square D. Improper wiring of GFCI may result in permanent damage to spa system box. Repair / replacement of spa system box is not covered under warranty when damage results from improper wiring.
  • Page 14: 120/240 Volt Systems

    120/240 VOLT SYSTEMS Attn: All electrical connections must be made by a licensed electrician. Failure to do so will void the spa warranty. Optional 120/240 Volt Models Franklin / Revere / Madison Special Note: Franklin, Revere, and Madison Models are pre-wired for 240 Volt installations from the factory.
  • Page 15: Volt Systems

    120/240 VOLT SYSTEMS - Plug-in Instructions Plug-In Instructions for 120V GFCI cord set (optional) Franklin / Revere / Madison 1. Electrical Requirements - Your spa requires a dedicated 120 volt AC 15 AMP electrical outlet and must have a separate, dedicated, grounded circuit having no other appliance connected in the circuit.
  • Page 16: Site Preparation

    Portable spa installation is simple when properly planned.To that end it is impor- tant that you read the following information carefully and consult with your Master Spas dealer. 1) Access - The actual dimensions of your new spa will determine the amount of space that is needed in moving the spa from curbside to its final installation area.
  • Page 17: Site Preparation

    Here again, with proper planning, no matter what room your spa goes in, it will be your favorite room. • Work with your Master Spas dealer and contractor to insure all local building, electrical and plumbing codes are met •...
  • Page 18: Installation Instructions

    This lasts approximately 5 minutes. 7.) Be sure the jets in your spa are opened. On all Master Spas: The jets open by turning the jet collar clockwise. On all Down East / Freedom Spas: The jets open by turning the jet collar counter clockwise.The smaller jets on the Down East line will...
  • Page 19 Due to the nature of water flow and hydro-therapy pumps, please be advised that air locking of pumps may occur. Master Spas has taken measures to reduce the possiblilty of this, but it still may occur, especially after refilling a spa.
  • Page 20: Water Chemistry Terms

    WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintence, here are some terms to help you. 1. Parts per million, or ppm: This is a form of measurement used in most pool or spa chemical readings. Best described as any one million like items of equal size and make up, next to one unlike item , but of equal size.
  • Page 21 WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintence, here are some terms to help you. 7. Filtration: Filters are necessary to remove particles of dust, dirt, algae, etc. that are continuously entering the water. If the spa is not operated long enough each day for the filter to do a proper job, this puts a burden on the chemicals, causing extra expense.
  • Page 22: Eco Pur

    SPA WATER MAINTENANCE Master Spas and Down East Spas * All Down East and Master Spas use the Eco Pur mineral filter(s). This section pertains specifically to maintaining water chemistry in spas that have the Eco Pur mineral filters. SPECIAL NOTE ECO PUR ™...
  • Page 23: Water Quality Maintenance Start-Up

    WATER QUALITY MAINTENANCE START-UP Master Spas and Down East Spas For ECO PUR ™ Water Purification System Optional: Fill spa using ECO PUR ™ Charcoal Pre-filter. Step 1: During initial filling of the spa with fresh water, add a sequestering agent such as Mineral Clear or Stain and Scale, etc.
  • Page 24: Advantages Of Eco Pur

    THE ADVANTAGES OF ECO PUR ™ MINERAL PURIFICATION Master Spas and Down East Spas • Destroys most bacteria, pathogens, algae, and fungi. • Removes many heavy metals like lead and mercury from water. • Removes calcium carbonate and hydrogen sulphide from spa water to protect heaters and equipment from precipitation.
  • Page 25: Water Quality Maintenance Schedule-Eco Pur

    WATER QUALITY MAINTENANCE SCHEDULE-ECO PUR ™ Master Spas and Down East Spas BEFORE EACH USE - Add 1 tablespoon of non-chlorine shock or 1/3 tea spoon of Dichlor to spa per 250 gallons. ONCE A WEEK - Add 3 Tablespoons of a non-chlorine shock or 1 tea spoon of Dichlor to spa per 250 gallons.
  • Page 26: Spa Water Maintenance Start-Up

    SPA WATER MAINTENANCE - START-UP Freedom Spas Read the spa owners manual first. Clean the surface with a spa general purpose cleaner or wipe down with a clean wet towel. Begin filling the spa with fresh water. If possible, do not use softened water. When the spa has 2 to 4 inches of water on the bottom, add the recommended amount of a sequestering chemical for that size spa.
  • Page 27: Spa Water Maintenance Schedule

    SPA WATER MAINTENANCE - SCHEDULE Freedom Spas DAY ONE 1. Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH / alkalinity increaser or decreaser 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be running on high speed during this time with the air controls closed.
  • Page 28 SPA WATER MAINTENANCE - SCHEDULE Freedom Spas DAY FOUR SKIP DAY FIVE 1. Test and adjust total alkalinity, if necessary, to between 80 and 150 ppm using the pH / alkalinity increaser or decreaser, 1oz. at a time. Wait 15 minutes, retest and adjust if necessary.
  • Page 29: Water Maintenance Trouble-Shooting

    SPA WATER MAINTENANCE TROUBLE-SHOOTING GUIDE Problem Possible Causes How To Fix It • Excessive Chlorine or • Shock water with non-chlorine Chlorine / Bromine Odor bromine levels shock treatment • Low pH • Adjust pH if necessary • Low levels of sanitizer •...
  • Page 30: Why Chemicals Are Important

    WHY ARE CHEMICALS IMPORTANT IN A SPA 1. Evaporation: As water evaporates, only pure water evaporates, leaving the salts, minerals, metals, and any unused chemicals behind. Adding water adds more salts, minerals, and metals. In time, the water can become saturated with these dissolved solids and can cause stains or scale to form on the walls of the spa or a scale build up inside the equipment.
  • Page 31: Maintenance Recommendations

    MAINTENANCE RECOMMENDATIONS Your spa requires periodic draining and cleaning to ensure a safe, healthy environment. It is recommended that you clean your spa at least every 180 days. Heavy bather load will require cleaning it more often. TO DRAIN YOUR SPA •...
  • Page 32: Winterizing Your Spa

    9.) Replace access panels. 10.) Cover spa to prevent water from entering the spa. *Disclaimer: Master Spas does not recommend winterizing your spa. If you choose to do so, any damage that may result is not covered under the spa warranty.
  • Page 33: Specifications

    MASTER SPA- SPECIFICATIONS Electrical Water Weight Therapy Model Dimensions Required Capacity Dry/Full Pumps Count LSI 557 66"x84"x32" 240 volt 50 amp 230 gallons 535lbs/2375lbs 2 pump LS 650 78"x84"x36" 240volt 50amp 370 gallon 740lbs/3700lb 4 pump LS 700 84"x84"x36" 240 volt 50 amp...
  • Page 34: Initial Start-Up

    MASTER SPA Indicator Lights Initial Start-up When your spa is first actuated, it will go into Priming mode (after displaying some configuration information). The Priming mode will last for up to 4 minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode.
  • Page 35 MASTER SPA Mode/Program This button is used to switch between standard, economy, and sleep modes. Press "Mode/Program" to enter mode programming, press "Cool" to cycle through to desired mode (LCD flashed until confirmed), then press "Mode/Program" to confirm selection. Standard mode maintains the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
  • Page 36: Indicator Lights

    LED light is on by itself, and rotates when the color wheel is on. If either light is left on, it will automatically turn off after 4 hours.The LSI 557 with the LED light option will only continuously change colors when on.
  • Page 37 MASTER SPA Secondary Filter Cycle Programming (cont.) Press "Mode/Prog" to see the "Program", "Filter 2", and "Start Time" icons. Proceed as above. Press "Mode/Prog" to see "Program", "Filter 2", and "End Time" icons. Adjust the time as done above. Pressing "Mode/Prog" will enter the new filter cycle times into the system and display the current water temperature.
  • Page 38 MASTER SPA Filtration Cycle Programming for LSI557 only The first filter cycle ("day") begins 6 minutes after the spa is powered up. The second filter cycle ("night") begins 12 hours later. Filter duration is programmable for 1 - 12 hours (F1 - F12). The default filter time is 2 hours. To program, press "Warm"...
  • Page 39: Diagnostic Messages

    MASTER SPA Diagnostic Messages Meaning Action Required Message No message on display. The control panel will be disabled until power Power has been cut off to the spa. returns. Time of day will be preserved for 30 days on your system. Spa settings are preserved on all systems.
  • Page 40: Diagnostic Messages

    MASTER SPA Diagnostic Messages (cont.) Meaning Action Required Message Inadequate water detected in heater. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Check for a dirty filter and clean if necessary.
  • Page 41: Periodic Reminder Messages

    MASTER SPA Periodic Reminder Messages (Press the “Mode” button to reset a displayed reminder) Frequency Message Action Required Every 7 days Test and adjust pH chemical levels per manufacturer’s instructions. Every 7 days Test and adjust sanitizer chemical levels per manufacturer’s instructions.
  • Page 42: Specifications

    DOWN EAST SPA - SPECIFICATIONS Electrical Water Weight Therapy Model Dimensions Required Capacity Dry/Full Pumps Count Concord 66"x84"32" 240 volt 50 amp 220 gallons 410lbs/1510lbs 1 pump Westport 77"x77"x32" 240 volt 50 amp 260 gallons 510lbs/2590lbs 1 pump Bar Harbor 78"x78"x35"...
  • Page 43: Initial Start-Up

    DOWN EAST (2 -3 PUMP SYSTEM) East Hampton / Portsmouth / Windsor / Exeter / Cape Cod (2 Pump System Plus Optional Circ. Pump Feature) East Hampton SE / Portsmouth SE / Windsor SE / Exeter SE/ Cape Cod SE (3 Pump System) Initial Start-up When your spa is first activated, it will go into priming mode (after displaying some configuration information).
  • Page 44 DOWN EAST (2 -3 PUMP SYSTEM) Mode This button is used to switch between standard, economy, and sleep modes. Press "Mode" to enter mode programming, press "Cool" to cycle through to desired mode (LCD flashes until confirmed), then press "Mode" to confirm selection. Standard mode maintains the desired temperature.
  • Page 45 DOWN EAST (2 -3 PUMP SYSTEM) Jets 2 Press the "Jet 2" button once to turn pump 2 on or off. If left running, the pump will turn off after 15 minutes. * Jets 3 Note: For SE models only. Press the "Jets 3" button once to turn pump 3 on or off.
  • Page 46 DOWN EAST (2 -3 PUMP SYSTEM) Clean-up Cycle When the pump is turned on by a button, a clean-up cycle begins 30 minutes after the pump is turned off or times out. The pump and the ozone generator will run for one hour. Ozone (optional) On most systems, the ozone generator (if installed) runs during filter cycles...
  • Page 47: Diagnostic Messages

    DOWN EAST (2 -3 PUMP SYSTEM) Diagnostic Messages Meaning Action Required Message No message on display. The control panel will be disabled until power Power has been cut off to the spa. returns. Time of day will be preserved for 30 days with a battery back-up on.
  • Page 48 DOWN EAST (2 -3 PUMP SYSTEM) Diagnostic Messages (cont.) Meaning Action Required Message Inadequate water detected in heater. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Check for a dirty filter and clean if necessary.
  • Page 49: Periodic Reminder Messages

    DOWN EAST (2 -3 PUMP SYSTEM) Periodic Reminder Messages (Press the “Mode” button to reset a displayed reminder) Frequency Message Action Required Every 7 days Test and adjust pH chemical levels per manufacturer’s instructions. Every 7 days Test and adjust sanitizer chemical levels per manufacturer’s instructions.
  • Page 50: Freedom Specifications

    FREEDOM SPA- SPECIFICATIONS Electrical Water Weight Therapy Model Dimensions Required Capacity Dry/Full Pumps Count Franklin 59"x78"x32" 120/240 volt 160 gallons 450lbs/1730lbs 1 pump 15/50 amp Revere 76"x76"x33" 120/240 volt 200 gallons 490lbs/2090lbs 1 pump 15/50 amp Madison 77"x77"x32" 120/240 volt 230 gallons 495lbs/2335lbs 1 pump...
  • Page 51: Initial Start-Up

    DOWN EAST AND FREEDOM - SINGLE PUMP SYSTEM Initial Start-up When your spa is first energized, it will go into Priming mode, indicated by Pr. The Priming mode will last for less than 5 minutes and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.
  • Page 52 DOWN EAST AND FREEDOM - SINGLE PUMP SYSTEM Mode Mode is changed by pressing the "Temp" button, then pressing the "Light" button. Standard Mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
  • Page 53: Diagnostic Messages

    DOWN EAST AND FREEDOM SINGLE PUMP SYSTEM Diagnostic Messages Meaning Action Required Message No message on display. The control panel will be disabled until power Power has been cut off to the spa. returns. Spa settings are preserved until next power up.
  • Page 54: Max Stereo System

    MAX STEREO SYSTEM Available on select Master Spa and Down East Models WARNING: Never remain in your spa longer than 15 minutes per session when the water temperature is above 98˚ F. If you wish to spend more time in your spa, whether enjoying music, watching tv, or just lounging, be sure to keep the spa water at or below body temperature (98.6˚...
  • Page 55: Max Stereo System

    MAX STEREO SYSTEM - (continued) Available on select Master Spa and Down East Models Note: Speakers should be in the down position before covering your spa. Failure to do so will result in damage not covered under the warranty. Note: UV rays may interfere with the operation of the Sony remote. The Sony Stereo is shipped with the detachable stereo face in the spa’s luggage pack.The stereo face must be inserted to operate any stereo funtions.
  • Page 56: Flat Screen Tv (Fst)

    FLAT SCREEN TV (FST) / STEREO SYSTEMS STS, LS 750 FST, and LSX 1050 Note: We have included the stereo and DVD owner’s manual with your spa. This should be read to see the specific operation of these components. Note: Do not place wet DVD’s or CD’s into the players at any time. Resulting damage will not be covered under warranty.
  • Page 57 FLAT SCREEN TV (FST) / STEREO SYSTEMS (continued) STS, LS 750 FST, and LSX 1050 Your FST spa (and any spa with a stereo) comes equipped with a locking, water resistant enclosure for the DVD player and stereo. We have installed an F-81 television coaxial cable connector located under the front panel for your convenience.This can be utilized if you wish to add a cable connection or satellite connection to your FST.
  • Page 58: Dolphin Remote

    DOLPHIN REMOTE All FST spas come with a Dolphin Remote Control.This remote operates off an RF frequency and controls TV, DVD, and Stereo functions. It will also oper- ate the therapy pumps and the light (using the “light” button).The blower, fiber, and opt.
  • Page 59 DOLPHIN REMOTE Power Key: (A) Turns the power on and off to the TV and DVD. NOTE: To engage power to the Sony CD player, use the TV/VID button in the CD device mode. Volume Keys: (B) Adjusts the volume in the selected device mode.
  • Page 60 DOLPHIN REMOTE Setup Key: (F) Use this key to program device codes and sequences (see page 61).Your Dolphin Remote has been preprogrammed at the factory for all components included.When the batteries are replaced, these components need to be reprogrammed. Device Mode Keys: (G) Select unit to control by pressing device key once.
  • Page 61 - the LED will blink twice after the last digit to confirm. 4.) Lock in the Code: To lock in the code, disengage power to device by pressing "POWER" key. Master Spas Device Codes Sony / CD 1397 T.View / DVD 0813...
  • Page 62 DOLPHIN REMOTE SYSTEM PROMPT To View TV Channels: Engage Power To Monitor 1) Select Device Mode (TV). 2) Press Power. 3) Select Guide. 4) Select desired channel. (C or I) Engage Power to CD Player 1) Select Device Mode (CD). 2) Press TV / Vid to engage power.
  • Page 63 DOLPHIN REMOTE DEVICE MODES / FEATURE KEYS CD Device Mode TV / Vid = Source - Aux / Power This key will engage power to the unit, as well as scroll between radio / CD mode. Vol Up / Down = Volume The main volume for the theater system is controlled through the CD Device Mode.
  • Page 64 DOLPHIN REMOTE TV DEVICE MODE Guide = TV / Catv This key will prompt TV to antenna or cable feed. TV / Vid = DVD / Video / Aux This key will prompt monitor to DVD channel. Power = On / Off This key will engage / disengage power to unit.
  • Page 65: Trouble Shooting Guide

    SPA TROUBLE SHOOTING GUIDE NOTHING ON THE SPA OPERATES- 1.) Check the control panel display for any messages. If there is a message, refer to the diagnostic section on that model spa.There you will find the meaning of the message and what action is to be taken. 2.) If there is no message on your control panel, check and reset the GFCI and house breaker.
  • Page 66: Trouble Shooting Guide

    SPA TROUBLE SHOOTING GUIDE SPA NOT HEATING * If the spas heater has failed, the majority of the time it will trip the GFCI breaker. If the spa is not heating and has not tripped the breaker, please follow these steps: 1.) Check the control panel for diagnostic messages.
  • Page 67: Regular Maintenance Procedures

    CLEANING DIVERTER VALVES Some Master Spas, Down East Spas, and Freedom Spas have diverter valves. Due to mineral deposits and grit/sand that may get into the internal parts of the diverter valve, it may become hard to turn or freeze up totally. In this case, it is necessary to remove the handle and cap of the diverter valve.
  • Page 68 REGULAR MAINTENANCE PROCEDURES CLEANING DIVERTER VALVES - cont. Turn the cap piece counter clockwise. It may be necessary to put a clean rag over the cap and turn it with a wrench. Once loose, the cap and handle can be pulled up out of the white plumbing fitting.
  • Page 69: Regular Maintenance Procedures

    REGULAR MAINTENANCE PROCEDURES CIRC PUMP DISCHARGE FITTING NEEDS TO BE CLEANED The circ pump discharge screen should be removed and cleaned if your spa is equipped with a circ pump.This screen can get clogged up due to mineral deposit or debris. It should be cleaned at least once every 180 days or when the spa is drained.
  • Page 70: Care Of Spa Cover, Spa Cabinet & Filter Cleaning

    VENTILATION OF COVER AND SPA. NOTE:The cover warranty is provided through the cover manufacturer and not through Master Spas.You will need to mail the cover warranty back to the cover manufacturer. CARE OF YOUR SPA CABINET Your quality spa cabinet is produced from hand-crafted cedar. It has been factory treated with a stain/sealer to maintain its appearance and to preserve its life.
  • Page 71: Spa Maintenance Records

    SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE DATE DATE Drain & Clean Spa Clean Filter Cartridges Change ECO PUR ™ Element Every 180 Days Soak Filter Cartridges in Solution Test GFCI Clean and Condition Spa Cover and Cabinet Miscellaneous Service America’s Leader In Luxury...
  • Page 72 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE M A S T E R S P A S America’s Leader In Luxury...

Table of Contents