Cub Cadet Domestic Series 7000 Service Manual page 82

Compact tractor
Hide thumbs Also See for Domestic Series 7000:
Table of Contents

Advertisement

Domestic Compact Electrical Systems
2.11. The key switch has four spade terminals.
See Figure 2.11.
Figure 2.11
The red wires with white trace (terminal A & B)
are fused constant hot-leads.
In the OFF position, no terminals are connected.
In the RUN position, only terminals B and C are
connected to, sending power through the red
wire with black trace to the lighting and acces-
sory circuits and pin # 18 (run input) on the
instrument panel.
The START position makes the "RUN" con-
tacts, and A terminal and D terminal are con-
nected to each other, sending power through the
orange wire to pin #16 (start input) on the panel.
2.12. The instrument panel is easily unplugged or
removed with the hood open. See Figure 2.12.
Molded connector
Mounting Bolts
Figure 2.12
2.13. The pin numbers are indicated on the molded
connector. See Figure 2.13.
back row: # 16 -> # 23
center row: # 9 -> # 15
near row:
# 1 -> # 8
"23"
"8"
2.14. Each number corresponds to a pin position on
the instrument panel. See Figure 2.13.
Pins on instrument
panel connection
77
"16"
Figure 2.13
Figure 2.14
"1"

Advertisement