3.4.2 Life clear mode
This mode is used for clearing life counters.
2: LIFE CLEAR
[ENTER]Key
(a)[ENTER]Key
1: LIFE CLEAR ALL
[>]Key
2: LIFE CLR EACH
[>]Key
(b)[ENTER]Key
1: SCAN(ADF)
2: SCAN(FB)
3: PRINT
4: DRUM
5: TONER
[>]Key
(a) Life all clear
Press the [ENTER] key, and the life counters of the printer and the life
counter of the scanner are set to 0.
Note: The value for Top void is not cleared.
(b) Life each clear
This mode is used to respectively clear the life counter of the printer
and the counter of the scanner. Select the desired counter and press
[ENTER] key.
Note: If "5: TONER" is executed, both "TONER PAGE" and "TONER
DOTCOUNT" are cleared.
3.5. Top void adjust
This mode is used for adjusting the top margin for printing.
Input range: [-1~06](mm)
1. Press the [ENTER] key and change the adjusting value using the
">" key and the "<" key.
TOP VOID ADJUST
[ENTER]Key
TOP VOID= 04(mm)
Adjust the value with the "<" the or the ">" key and press the [ENTER] key.
3.6. Print adjust
This mode is used to set some values about the printer.
PRINT ADJUST
[ENTER]Key
FAN MD_TIME SET
TRAY TEMP.
[>]Key
[>]Key
PARAMETERL IST
LI FE CLE AR
[ENTER]Key
LI FE CLE AR
[>]Key
[ENTER]Key
LI FE CLE AR
[>]Key
[ENTER]Key
LI FE CLE AR
[>]Key
[ENTER]Key
LI FE CLE AR
[>]Key
[ENTER]Key
LI FE CLE AR
BYPASS TEMP.
[>]Key
[>] Ke y
FLICKER ADJUST
[>]Key
3.6.1 Fan MD time set
This mode is used to set the driving time of the fan motor after stop-
ping the main motor.
FAN MD_TIME SET
Default value: 02
Input Range: MIN: 00, MAX: 63
Unit: Minute
After entering the value, the Printer Adjust mode ends and the next
mode is displayed.
3.6.2 Tray temp.
This mode is used to set the temperature of fixing when printing from
the standard tray.
TRAY TEMP.
[ENTER]Key
ON temp.=190 deg
[>]Key
OFF temp.=190 deg
[>]Key
FEED temp.=190 deg
[>]Key
TIME=10(s)
[>]Key
1. ON TEMP.
The temperature to start turning on the heater.
Default value: 190
Range: MIN: 170, MAX: 233
Unit: Centigrade
2. OFF TEMP.
The temperature to start turning off the heater.
Default value: 190
Range: MIN: 170, MAX: 233
Unit: Centigrade
3. FEED TEMP.
The temperature to start feeding the paper.
Default value: 190
Range: MIN: 170, MAX: 233
Unit: Centigrade
4. TIME
Warming up time after reaching the temperature that the printing
can be done.
Default value: 10
Range: MIN: 10, MAX: 63
Unit: Second
2 – 13
AM-900U
[ENTER]Key
FAN MD_TIME( 02 )
Cursor position
Input temperature using the numeric keys
Input temperature using the numeric keys
Input temperature using the numeric keys
Input temperature using the numeric keys