Hexad
ecimal
ID
notatio
n
10
(0x0a)
11
(0x0b)
12
(0x0c)
13
(0x0d)
14
(0x0e)
15
(0x0f)
19
(0x13)
20
(0x14)
21
(0x15)
60
Type
Log item
Error
Rebuild stopped
with error. New
device failed.
Error
Rebuild stopped
because logical
drive failed.
Error
A physical disk has
failed.
Infor
A new physical disk
mati
has been found.
on
Infor
A physical disk has
mati
been removed.
on
Infor
A previously
mati
configured disk is
on
now available.
Warn
SCSI command
ing
timeout on hard
device.
Error
SCSI command
abort on hard disk.
Warn
SCSI command
ing
retried on hard disk.
Description
Rebuild terminated
abnormally due to a
bad hard disk for the
rebuild.
The source disk of the
rebuild failed.
A hard disk failed.
A new hard disk was
detected. The following
are possible causes:
• The controller was
powered on.
• The system was
restarted.
A hard disk was
removed.
A hard disk is now in
"Unconfigured" state.
A command timeout
was detected.
• The user aborted the
command.
• The firmware
aborted the com-
mand to recover
from an error.
• A device aborted the
command.
• The command timed
out.
• A bus reset occurred.
• A device reset
occurred.
Action
Replace the hard disk
again and re-execute the
rebuild process.
Take corrective action
using the Multi Dead
function.
Replace the Dead hard
disk and rebuild.
Not required.
Not required.
Not required.
Because the firmware is
implementing a recovery,
there is no problem as
long as there are no Dead
hard disks.