Table 7-16.
When you specify variables port-name.host-group-id, you can narrow the
range of LU paths whose monitoring data are to be exported. port-name is
a port name. host-group-id is the ID of a host group. The host group ID
must be a hexadecimal numeral. The colon (:) indicates a range. For
example, CL1-C.01:CL1-C.03 indicates the range from the host group #01
of the CL1-C port to the host group #03 of the CL1-C port.
Ensure that the value on the left of the colon is smaller than the value on
the right of the colon. The smallest port-name value is CL1-A and the
largest port-name value is CL4-r. The following formula illustrates which
port-name value is smaller than which port-name value:
CL1-A < CL1-B < ... < CL2-A < CL2-B < ... < CL3-a < CL3-b < ... < CL4-
a < ... < CL4-r
For example, you can specify URLU CL1-C.01:CL2-A.01 , but you cannot
specify URLU CL2-A.01:CL1-C.01 . Also, you can specify
URLU CL1-C.01:CL1-C.03 , but you cannot specify URLU CL1-C.03:CL1-C.01 .
If port-name.host-group-id is not specified, the monitoring data of all the
volumes (LUs) will be exported.
URLDEV [[LDKC-CU-id]:[LDKC-CU-id]][ ...]
Use this operand when you want to export statistics about remote copy
operations which are displayed in the UR Monitor window and the URz
Monitor window. By using this operand, you can export monitoring data
about remote copy operations performed by Universal Replicator and
Universal Replicator for IBM z/OS at volumes controlled by each CU. When
statistics are exported to a ZIP file, multiple ZIP files whose names are
beginning with URLDEV_ will be output. For details on the statistics exported
by this operand, see Table 7-17.
When you specify variables LDKC-CU-id, you can narrow the range of
LDKC:CUs that control the volumes whose monitoring data are to be
exported. LDKC-CU-id is an ID of a LDKC:CU. The colon (:) indicates a
range. For example, 000:105 indicates LDKC:CUs from 00:00 to 01:05.
Ensure that the LDKC-CU-id value on the left of the colon is smaller than
the LDKC-CU-id value on the right of the colon. For example, you can
specify URLDEV 000:105 , but you cannot specify URLDEV 105:000 .
If LDKC-CU-id is not specified, the monitoring data of all the volumes will
be exported.
Examples
The following example exports statistics about host bus adapters and SPM
groups:
group PortWWN
group PPCG
7-52
Hitachi Universal Storage Platform V/VM Hitachi Performance Manager User's Guide
Using the Export Tool

Advertisement