Detail Settings

Application Settings Page

Use this page to specify settings for each application. Only the application selected as the "Target
Application" in the Basic Settings page is shown on this page.
When WebView Livescope is selected
"Set Service time for user"
When you want to set service reception for WebView
Livescope users, tick this option and specify the From
and To times.
52
WebView Livescope
"Video Transmission Port"
Sets the TCP port number for the WebView
Livescope video transmission protocol.
Enter an integer between 1 and 65535.
The default setting is 65310.
"Camera Control Port"
Sets the TCP port number for the WebView
Livescope camera control protocol. Enter
an integer between 1 and 65535. The
default setting is 65311.
"Maximum Clients"
Sets the maximum number of clients that
can be connected using the WebView
Livescope protocol. Enter an integer
between 1 and 20.
"Control Queue Length"
Sets the length of the queue when multiple
clients are waiting for control authority
under the WebView Livescope protocol.
Enter an integer between 0 and 20.
"Maximum Frame rate (fps)"
Sets the maximum number of frames
captured per second under the WebView
Livescope protocol. Enter a fixed point
between 0.1 and 30. The maximum frame
rate is 30 fps.
"Maximum View Time (sec)"
Sets the maximum time for which a
WebView Livescope protocol connection
can be maintained. Enter an integer
between 1 and 65535. A setting of 0
disables the time limitation (unlimited
connection time).
"Maximum Camera Control Time (sec)"
Sets the maximum time for which camera
control authority can be maintained under
the WebView Livescope protocol. Enter an
integer between 1 and 3600.
"Still Video Capture Delay Wait Time (msec.)"
When the GetStillImage command has
been requested, this setting specifies the
delay to allow the camera to stabilize
before still video capture is performed.
Enter an integer between 1 and 10000.
The
maximum
delay
is
10000
milliseconds.
View-Windows is for sale in Japan only, it cannot be used in any other country.
When VIEW-Windows 1.21 is selected
c
Take care when changing port numbers. Port numbers do not need to be
changed in normal use.
Note
Click the [OK] button to change the settings. To discard the changes, click the
[Cancel] button. This returns you to the settings title page.
Detail Settings
VIEW-Windows 1.21
"Video Transmission Port"
Sets the TCP port number for the VIEW-
Windows 1.21 video transmission protocol.
The default setting is 5111.
"Camera Control Port"
Sets the TCP port number for the VIEW-
Windows 1.21 camera control protocol.
Enter an integer between 1 and 65535.
The default setting is 5110.
3
"Switcher Control Port"
Sets the TCP port number for the VIEW-
Windows 1.21 switcher control protocol.
Enter an integer between 1 and 65535.
The default setting is 5120.
"Maximum Clients"
Sets the maximum number of clients that
can be connected using the VIEW-
Windows 1.21 protocol. Enter an integer
between 1 and 10.
"Maximum Frame rate (fps)"
Sets the maximum number of frames
captured per second under the VIEW-
Windows 1.21 protocol. Enter a real
number between 0.1 and 30.
53