4-W|RE
CONNECTION
iNSTRUCTiONS
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting
to a 4-wire electrical system %r a
new branch-circuit
or mobile home use a 4-wire connection.
1 Follow the power supply cord kit manufacturer's
Installation
Instructions
and install the strain relief clamp on the cord. See
Figure 8.
2 Connect the end connectors
for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 9.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
failure or loss of electrical
connection
may
occur if these 3 nuts are loosened or removed.
3 You must disconnect
the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw. See Figure 9.
4 Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the
frame where the ground screw was originally
installed.
See
Figure 9.
5 Make sure all screws are tightened
securely and replace the
rear access cover and secure with screw. See Figure 7.
3-WIRE
CONNECTION
iNSTRUCTiONS
For existing installations
ONLY, refer to Figure 10.
1 Follow the power supply cord kit manufacturer's
Installation
Instructions
and install the strain relief clamp. See Figure 10.
2 Connect the end connectors
for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 10.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
failure or loss of electrical
connection
may
occur if these 3 nuts are loosened or removed.
3 A ground strap is installed on this range which connects the
center terminal
of the neutral
terminal
block to the range
chassis. The ground
strap is connected
to the range by the
iNSTALLATiON
MANUAL
center, lowest screw. See Figure 10. The ground strap must
not be removed unless National,
State or Local Codes do not
permit use of a ground strap.
If the ground
strap is removed for any reason,
a
separate ground wire must be connected to the separate ground
screw attached to the range chassis and to an adequate ground
source.
Make sure all connections
are tightened
securely and replace
the rear access cover and secure with screw. See Figure 7.
3 & 4-WIRE
PERMANENT
WiRE
CONNECTIONS
3-_ire
permanent
connection
- follo_
steps 1, 2 and 5 belong.
4-wire
permanent
connection
- follow all steps below.
Before wiring the range, review the suggested power source location
drawings
in Figure 2. If connecting
to a 4-wire electrical
system:
1 Follow the manufacturer's
Installation Instructions for installing
the strain relief clamp.
2
Strip insulation
away from the ends of the permanent
wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections.
Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 11.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
failure or loss of electrical
connection
may
occur if these 3 nuts are loosened
or removed.
For 3-wire permanent connection
skip steps 3 and 4
and continue with step 5.
3
Disconnect
the ground
strap. Remove the factory installed
ground screw and plate to release the factory installed
copper
ground strap from frame of the range. Cut and discard
the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
4
Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 12. Be sure
to install using the same hole in the frame where the ground
screw was originally
installed.
5
Make sure all connections
are tightened
securely and replace
the rear access cover. See Figure 7.
Non-terminated
field wire compression
connections
must be set at approximately
90 in./lb.
Connect
line 1 here
Cut ground strap.
Discard ground
strap and ground
plate
Connectc
insulated copper
ground wire with
ground screw here
i
i
Figure
9
"
Note: InstNI strain
relief clamp. Center
or white wire must
always be attached to
the center terminal on
"TerminN block
Connect line 2 here
_Connect
neutral
(white or center) here
A user supplied strain
relief clamp must be
installed at this
location. It requires 1
3/8" (3.5 cm) diameter
cord kit hole.
Connect line
1 here.
Ground strap
Note: Install strain
relief clamp. Center
must always be
attached to the
center terminal on
block.
Figure
t 0
5
1
line 2 here.
I
Connect neutral
A user supplied
strain relief clamp
It
requires 1 3/8"
(3.5 cm) diameter
cord kit hole.