iNSTALLATiON
MANUAL
The installer or consumer
is responsible
for connecting
the power
supply cord to the connection
block located behind the back panel
access cover.
This range may be connected
by means of permanent
"hard wiring"
(flexible armored or nonmetallic
shielded copper or aluminum cable),
or by means of a power supply cord kit. Only a power supply cord kit
rated at 240 volts or 208 volts and 50 amperes and marked for use
with ranges shall be used. Cord must have either 3 or 4 conductors
to match electric receptacle.
The power cord kit is not included
so
must be purchased
at an appliance store.
For mobile homes, new installations,
recreational
vehicles or areas
where local codes do not permit grounding through neutral, a 4 con-
ductor power supply cord kit rated at 240 volts or 208 volts minimum,
50 amperes and marked for use with ranges should be used.
Terminals
on end of wires must be either closed loop or open-end
spade lugs with upturned
ends. Cord must have strain-relief
clamp.
The range connection
opening should be 1 3/8-inches.
_Risk
of fire or electrical
shock
exists
if all
incorrect
size range cord kit is used, the installation
instructions
are not followed precisely
or a strain
relief clamp
is not used.
Do not loosen the nuts which secure the factory-
installed
range wiring
to the terminal
block while connecting
range.
Electrical
failure
or loss of electrical
connection
may
Occur.
ELECTRICAL
SHOCK
HAZARD
° DISCONNECT
POWER
TO THE CIRCUIT
BREAKER
OR FUSE BOX BEFORE
MAKING
THE ELECTRICAL
CONNECTION.
• Electrical
ground
is required
on this range.
° Do not connect to the electrical supply until range is permanently
grounded.
° This range
must be connected
to a grounded,
metallic,
permanent
electrical
system or the grounding
connector of the
power cord should be connected
to the grounding
terminal or
wire lead on the range.
° Failure to heed these warnings
could result in a fire, personal
injury or electrical
shock.
Ntin_late
2081240
VOLT CONNECTION
iNSTRUCTIONS
The range can be set for 208V or 240V. The voltage setting for your
range is pre-set at 240V from the factory. Follow these steps to
change the voltage setting.
1 Locate the voltage switch on the lower back side of the range.
2
Remove the screw and rotate the switch plate 180 ° as indicated
in the Figure 4.
3
Reinsert
the switch plate and replace
screw as indicated
in Figure
5. The voltage
setting is indicated
by the visible
marking.
screw
screw
Figure
4
Figure
5
3 & 4-WIRE
ELECTRICAL
WALL RECEPTACLE
TYPES &
RECOMMENDED
MOUNTING
ORiENTATiON
ON WALL
Figure
6A illustrates
4-wire
receptacle
required
for new and
remodeled
installations.
Figure 6B illustrates
3-wire receptacle
that is allowed for existing
installations.
4-wire wall receptacle
(14-50R)
Figure
SA
3-wire wall receptacle
(10-50R)
Figure
6B
ACCESS
TO TERMINAL
BLOCK
Loosen
screw on rear access cover and pull down as illustrated
in
Figure 7 to access terminal block wiring connection.
strain relief clamp
MODFL
AND
SERIAL
NUMBI:R
LOCATION
The rating plate, including
model and serial number, is located on
the faceplate behind the Microwave
Drawer front.
(
/