Download Print this page

Kenmore 790.75722991 Installation Instructions Manual

Hide thumbs Also See for 790.75722991:

Advertisement

For Models
with
4 Standard
Sealed
Top Burners
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
THIS CONVERSION
KIT MUST
BE INSTALLED
BY A QUALIFIED
SERVICE TECHNICIAN
IN ACCORDANCE
WITH THE MANUFACTURER'S
INSTRUCTIONS
AND ALLAPPLICABLE
CODES AND
REQUIREMENTS
OFTHE AUTHORITY
HAVING
JURISDICTION.
FAILURE TO FOLLOW INSTRUCTIONS
MAY RESULT IN FIRE, EXPLOSION
OR PRODUCTION
OF CARBON
MONOXIDE
CAUSING
PROPERTY
DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE. THE QUALIFIED
SERVICE AGENCY
IS RESPONSIBLE
FOR TH E PROPER INSTALLATION
OF THIS KIT. THE INSTALLATION
IS NOT PROPER AND COMPLETE
UNTIL
THE OPERATION
OF THE CONVERTED
APPLIANCE
IS CHECKED
AS SPECIFIED
IN THE
MANUFACTURER'S
INSTRUCTIONS
SUPPLIED
WITH THE KIT.
BEFORE PROCEEDING
WITH THE CONVERSION,
SHUT OFF THE GAS SUPPLY BEFORE
DISCONNECTING
ELECTRICAL POWER TO THE RANGE.
BE SURE BOTH POWER SUPPLIES ARE OFF
BEFORE INSTALLING
THE CONVERSION
KIT. FAILURE TO DO SO COULD CAUSE SERIOUS
BODILY
INJURY.
This kit contains
the following:
Quantity
Description
Part Number
1
4
4
4
Top Burner Orifice Marked
0.89 mm (7,500
BTU*)
*For operation at elevations above 2000 ft., appliance rating shall be
reduced at the rate of 4 percent for each 1000 ft. above sea level.
Installation
Instructions
Restrictor-Burner
Screw-Restrictor
Choke-Burner:
Small (7,500
BTU) Top Burners
316010802
316105828
316011600
316064200
316056700
Tools Required:
#1 Phillips Head Screwdriver (small) _--:=_
5/8" Open
End Wrench
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver _
_]
7qo.-r.qTizTq l/,; 'Flo.?'...<'7,z,/qq/;
7clo.7572- _
lj "7_o. T57Z_-_q /
790.7,._77-.1qq)_;
79o. 7573-3.9q2-.,"
9o. 7xTz,Tq 2-;
7go. 75"72_'_'q2.
Espahol-
P_ginas 7-12
PIN 316105828
(0001)

Advertisement

loading

Summary of Contents for Kenmore 790.75722991

  • Page 1 For Models with 4 Standard Sealed Top Burners INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. THIS CONVERSION KIT MUST BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER'S...
  • Page 2 to Convert the Range for use with LP/Propane Gas 1. Convert the Pressure Regulator To access the regulator,remove the kick panel, storage drawer or warmer drawer. If equipped with a broiler drawer, open drawer completely. For models equipped Front Access with warmer drawer,...
  • Page 3 2. Convert Surface Burners with Use caution when replacing the burner cap Propane Gas (see Figure so the electrode is not damaged, 5/8" [Ir_ Unlike the standard gas range, THIS COOKTOP Burner F lame S ize _ IS NOT REMOVABLE. Do not attempt to remove...
  • Page 4 5. Reconnect Gas and Electrical Supply to Test to verify if "LOW" setting should be adjusted Push in and turn control to LITE until burner ignites. Range. Push in and auickly turn knob to LOWEST POSITION. Leak t estingoftheappliance s hall b econducted a ccording If burner goes out, reset control to OFF.
  • Page 5 8. Air Shutter-Broil Burner Observe the flame to determine if the broiler burner Burner flame is properly adjusted. It should be steady with approximately 1" blue cones and no yellow or orange flame tips. ® Locking Screw Air Shutter Orifice Hood (Spud) FIGURE 9 FIGURE 1 1...
  • Page 6 Replace Kick Panel, Storage Drawer or Warmer Drawer: (instructions for warmer drawer) a. Pullthe bearingglidesto the front of the chassis glide (see picture below). b. Align the glide on each side ofthe drawer with the glide slots on the range. Push the drawer into the range until levers "click"...