Chapter 4: Web-Based Management
OBJECT
Over Temperature
Protection
Power limit mode
Power Allocation
PoE Function
Priority
Device class
Current(mA)
Consumption [W]
Power Limit
NOTE:
For GE-DS-242-PoE, the total PoE power reservation from Port-1~24 is up to
380W.
118
DESCRIPTION
Enable / Disable over temperature protection.
When the PoE temperature unit 1 / unit2 over 70 degree C then PoE
power budget will be changed by 3 segments as following.
Over 70 Degree C power budget 180 Watts
Over 73 Degree C power budget 170 Watts
Over 76 Degree C power budget 160 Watts
Allow to configure power limit mode of Web Smart Device. It can
choose :
Port Priority Deliver PoE power by port priority setting
Total Limit. Set limit value of the total POE port provided power to
the PDs.
Show the total watts usage of PoE Switch.
Can enable or disable the PoE function.
Set port priority for the POE power management
It can choose the "port priority", value is :
Critical
High
Low
High priority is "Critical".
Class 0 is the default for PDs. However, to improve power management
at the PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the
maximum power that the PD will draw across all input voltages and
operational modes. A PD shall return Class 0 to 3 in accordance with
the maximum power draw as specified by Table 4.1.
It shows the PoE device current Amp.
It shows the PoE device current watt.
It can limit the port PoE supply watts.
Per port maximum value must less 15.4, total ports values must less
than the Power Reservation value.
Once power overload detected, the port will auto shut down and keep
on detection mode until PD's power consumption lower than the power
limit value.
GE-DS-242-PoE Managed Ethernet Switch User Manual