4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the bottom. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Specifications

Power Supply
Input
Rated AC Phase and line frequency (Hz)
Rated Input Voltage (U1) and rated Input Current (I1)
and I1 eff at rated output. I1 eff used to determine
power cord rating
Power Factor/kVA/kW at Rated Output
Peak kW at Arc Stretch
Output
Rated Open Circuit Voltage (U0) Type
Output Characteristic
Rated Output Current (I2)
Rated Output Voltage (U2)
Output Current Range
Duty Cycle at 104 F (405C) and Rated Conditions
(U1, I1, U2, I2) based on a 10 minute period
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − INSTALLATION
Volts AC RMS − (U1)
Volts AC RMS − (U1)
400 Volts DC/Electrode Negative
1 − 3−Phase
Amps RMS − (I1)
208 VAC 1−Phase
230 VAC 1−Phase
208 VAC 3−Phase
230 VAC 3−Phase
380 VAC 3−Phase
460 VAC 3−Phase
575 VAC 3−Phase
Power Factor
208 VAC 1−Phase
230 VAC 1−Phase
208 VAC 3−Phase
230 VAC 3−Phase
380 VAC 3−Phase
460 VAC 3−Phase
575 VAC 3−Phase
15.5 kW
Constant Current
60 A
140 Volts DC
20 − 60 A
Duty Cycle %
Amps DC − (I2)
40
50
60
100
100
−−
50 / 60 Hz
I1 eff
47.4
30
42.2
26.7
27.5
19.4
25
17.7
15
11.6
12.4
9.6
9.8
7.6
kVA/kW
0.98
9.9 / 9.7
0.98
9.7 / 9.6
0.95
9.9 / 9.5
0.95
9.9 / 9.5
0.95
9.9 / 9.4
0.95
9.9 / 9.4
0.95
9.8 / 9.3
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
Volts AC RMS −
(U1)
208−230 VAC
60 A
1−Phase
208−230 VAC
60 A
3−Phase
380−575 VAC
60 A
3−Phase
208−230 VAC
50 A
1−Phase
208−575 VAC
50 A
3−Phase
OM-242 880 Page 11

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectrum 875 Auto-Line and is the answer not in the manual?

Questions and answers

Mursel
February 28, 2025

Miller plazma 875 sikakliq ışığının yanması sonrunu

User image 67c18754efeb5
2 comments:
Mr. Anderson
February 28, 2025

The indicator lights on the Miller Electric Spectrum 875 Auto-Line plasma cutter provide status information:

- Power light flashing at two quick cycles with a one-second pause: Input power is above 300V AC or below 156V AC. A qualified technician should check the input power.
- Pre-charge PTCs overheated: Allow 15 minutes for the unit to cool.
- Pressure status light flashing at two quick flashes with a one-second pause for 15 seconds: Unit-regulated pressure is too high. Check input pressure (90-120 PSI). If the issue persists, a Factory Authorized Service Agent should inspect the unit. Reset the power switch.
- Pressure status light flashing steadily for 15 seconds or until the torch trigger is pressed: Regulated pressure is too low. Check for leaks in the torch and ensure input pressure is between 90-120 PSI during cutting.

These lights help diagnose power and pressure issues in the plasma cutter.

This answer is automatically generated

Mürsel
February 28, 2025

@Mr. Anderson Cihazı ise salarken sıcaklık ışığı yanıyor ve sönmüyor bu sorunda Cihazın işlemesini engelliyor. Soru şuki Cihazı işe salarken neden temp (sıcaklık ışığı) yanıyor ve bu sorunun çaresi ne? Bununla bağlı yardımcı ola bilen varmi??

User image 67c1b92c03cc6

This manual is also suitable for:

Spectrum ice-60t/tm torchCe-60tCe-60tm

Table of Contents

Save PDF