System Event Message
Failure reading from data volume.
Failure writing to data volume.
Checksum verification on metadata failed.
Optimization engine log replay failed.
Decompression of datastore failed <
Failed to clean active datastore <
Negative reference on datastore <
variable >. Count: < variable >.
type: <
variable > contains negative stream
Datastore <
reference count. Record type: <
variable >.
<
variable > total reference count reached
Datastore <
variable >. Count: < variable >.
threshold. Record type: <
Entering Maintenance mode due to failure in
processing logs.
Failed to acquire optimizer pipeline. Error: <
Failed to create optimizer event. Type: <
variable >.
Error: <
variable > timed out after
Task execution in fiber <
variable > milliseconds (ms). Restarting file server.
<
Memory allocation failure.
Background compression started.
Background compression completed.
Optimization initialized on container <
Optimization terminated on container <
Cleaner process started as per schedule, will be active
variable >.
until <
Cleaner process stopped as per schedule, will restart
variable >.
at <
variable >.
Cleaner aborted at <
Description/Meaning or Action
Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Contact Dell Support for assistance or repair the filesystem.
For repairs, see
Contact Dell Support for assistance or repair the filesystem.
For repairs, see
variable >.
Contact Dell Support for assistance or intervention.
variable >.
Contact Dell Support for assistance or intervention.
variable >. Record
Contact Dell Support for assistance or repair the filesystem.
For repairs, see About the DR Series Maintenance Mode.
Informational message. No user intervention is required.
variable >. Count:
Informational message. No user intervention is required.
Contact Dell Support for assistance or intervention.
variable >.
Contact Dell Support for intervention or assistance.
variable >,
Contact Dell Support for intervention or assistance.
Filesystem restarted. Collect diagnostics log file bundle, and
upload diagnostics log file bundle to Dell Support.
Collect diagnostics log file bundle.
Informational message. No user intervention is required.
Informational message. No user intervention is required.
variable >.
Informational message. No user intervention is required.
variable >.
Informational message. No user intervention is required.
Informational message. No user intervention is required.
Informational message. No user intervention is required.
The DR Series system should enter Maintenance mode, and
Cleaner process will restart.
About The DR Series Maintenance
About The DR Series Maintenance
Mode.
Mode.
163