System Event Message
Container replay failed for container <
Failure—Name Space subsystem initialization failed.
Inconsistencies were found in the Name Space.
System entering Maintenance mode—Name Space
log replay failed.
System entering Maintenance Mode—Name Space
transaction failure.
Failure—failed to commit Name Space transaction.
Filesystem has reached the maximum supported
number of Name Space entries.
Filesystem has recovered from a lack of available
Name Space entries.
Internal attributes of some files were found to be
corrupt. The DR Series system will not allow the
setting or removing of Attributes or ACLs on files that
have corrupt attributes.
Replication resync started for container <
Replication internal resync started for container
<
variable >.
Replication resync completed for container <
Replication internal resync completed for container
variable >.
<
Failure creating replication snapshot for container
variable >.
<
Failure deleting replication snapshot for container
variable >.
<
Replication client connected for container <
Replication client disconnected for container
variable >.
<
Replication server connected for container <
Description/Meaning or Action
variable >.
Informational message. No user intervention is required.
Contact Dell Support for assistance or intervention.
Informational message. No user intervention is required.
Contact Dell Support for assistance or intervention.
Please schedule a filesystem consistency check using the DR
Series system CLI maintenance --filesystem --start_scan
command.
Contact Dell Support for assistance or intervention.
Contact Dell Support for assistance or intervention.
Contact Dell Support for assistance or intervention.
Please clean up the filesystem to allow new file and directory
create operations. If this condition persists, contact Dell
Support for assistance or intervention.
Filesystem create operations will now be allowed. Contact
Dell Support for assistance or intervention.
To find all files with corrupt attributes and to clear the state,
please perform a maintenance scan using the DR Series
system CLI maintenance --filesystem --start_scan command.
Contact Dell Support for assistance or intervention.
variable >.
Informational message. No user intervention is required.
Informational message. No user intervention is required.
variable >. Informational message. No user intervention is required.
Informational message. No user intervention is required.
If condition persists, reduce number of inodes, or contact Dell
Support for assistance or intervention.
If condition persists, reduce number of inodes, or contact Dell
Support for assistance or intervention.
variable >.
Informational message. No user intervention is required.
Verify that the ports for replication (9904, 9911, 9915, and 9916)
and OST (10011 and 11000) operations have been enabled. If
issue persists, contact Dell Support for assistance or
intervention.
variable >. Verify that the ports for replication (9904, 9911, 9915, and 9916)
and OST (10011 and 11000) operations have been enabled. If
issue persists, contact Dell Support for assistance or
intervention.