Alert Message
number > is unplugged.
Power Supply <
number > failed.
Fan <
number > is missing.
Fan <
Abnormal network errors detected on Network Interface
Controller <
number >.
Network Interface Controller is missing.
Network Interface Controller <
Network Interface Controller <
Network Interface Controller <
CPU <
name > failed.
name > is missing.
CPU <
name > failed.
DIMM <
name > is missing.
DIMM <
name > failed.
Temperature probe <
name > failed.
Voltage probe <
152
name > is disconnected.
name > is disabled.
name > driver is bad.
Description/Meaning or Action
If this does not resolve the issue, replace the designated
power supply.
Reconnect the power cable to the designated
power supply unit if it is disconnected.
Ensure that there is input AC power at the power
cable.
Use a different power cord.
Verify that the designated cooling fan is present
and is installed correctly.
Verify that the designated cooling fan spins up and
runs.
If this does not resolve the issue, replace the designated
cooling fan.
Attach or replace the designated missing cooling fan.
The Network Interface Controller errors could be caused
by network congestion or by packet errors.
Check your network. If that does not resolve the
problem, then replace the NIC.
If the NIC is embedded, the DR Series system
appliance requires service.
Remove and reinsert the NIC.
If this does not resolve the problem, replace the
NIC.
Connect it to a network and/or check your network
switches or routers for any network connectivity issues.
Enable the port on the designated NIC.
Upgrade the DR Series system appliance (in the Software
Upgrade page, and click Start Upgrade).
Replace the designated failed processor.
Reinsert or replace the designated missing processor.
Replace the designated failed DIMM (Dual In-line Memory
Module) device.
Reinsert or replace the designated DIMM device.
The memory capacity of the storage appliance is
below the minimum required for correct operation.
The storage appliance requires service.
The storage appliance requires service.
The storage appliance requires service.