Emergency Recording Setup; Emergency Recording; Long Pre-Alarm Recording - Mitsubishi Electric DX-TL5000E Installer Manual

Hide thumbs Also See for DX-TL5000E:
Table of Contents

Advertisement

Recording (continued)

Emergency Recording Setup

This item is used to set the emergency recording settings.
When the EMERGENCY terminal is grounded by the alarm
sensor while both of the MAIN switch on the rear panel
and the POWER button on the front panel are turned ON,
emergency recording starts automatically overriding all the
other settings even during timer recording or the unit is in
stop mode.
• Emergency recording is not performed while the MAIN
switch or POWER button is turned OFF or while timer
recording stand-by mode.
• The setting of the <Recording> menu cannot be
changed during normal recording or alarm recording.
When changing setting during recording, stop
recording in case of normal recording. In case of alarm
recording, when the "Alarm Input" in the <Recording>
menu is set to "Off," the alarm input cannot be
accepted for 5 minutes. When you stop recording
during this time, the setting change of the <Recording>
menu is available.
Setup Menu
1
Recording
5
Emergency Recording Setup
D
(Recording)
1. Select the frame or field recording.
step
2. Set the long pre-alarm recording time in "Pre-alarm
step
Duration."
0 min: Does not execute the long pre-alarm
recording.
3. Set the emergency recording time in "Post-alarm
step
Duration."
4. Set the maximum recording rate.
step
(Camera Setting)
5. Set the recording camera.
step
• The button function changes between "All Off"
and "All On" each time you select this button.
6. Select "Execute."
step
• The preview screen appears.

Emergency recording

1) The picture grade is "Super" and the recording rate is
set to the value obtained by dividing the maximum
emergency recording rate by the number of specified
cameras.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
54
Emergency Record Settings
• When the long pre-alarm area is set in the main
device, the emergency recording data is stored in the
LPA area and is automatically locked in 512 MB unit
including the emergency recording data in order to
prevent overwriting the data.
In LPA area, the data is always recorded at the rate
set for alarm recording regardless of an input of the
emergency signal. Therefore, when the emergency
recording is started from the mid-part of the data block,
the data recorded before the ground of the
EMERGENCY terminal is stored in the locked area
along with the emergency recording.
• When you set the long pre-alarm recording time
without setting the long pre-alarm area, long pre-alarm
recording is carried out using the alarm area for alarm
recording, so long pre-alarm recording for long time
period is not performed.
• When emergency recording is carried out using the
long pre-alarm area, data is not stored chronologically
and alarms are listed out of sequence. Be careful
when searching for the desired picture.
• When power failure occurs during emergency
recording, the emergency recording is cancelled after
returning from the power failure.
• When emergency recording is input during timer
recording, the end time of the timer recording is
extended until the emergency recording is completed.
The timer recording is completed after completing the
emergency recording.
2) Cameras to be used
Cameras which are set in <Emergency Recording
Setup> menu are used.
3) During emergency recording:
• "E-REC" is displayed on the screen in red.
• The camera number buttons and camera number dis-
play on the screen which are used for emergency re-
cording flash.
4) Emergency recording is registered in the alarm list and
displayed in magenta.

Long pre-alarm recording

Long pre-alarm recording is a function to perform pre-alarm
recording for a maximum of 60 minutes before the emer-
gency recording is started.
• To set long pre-alarm area, set the desired capacity
in "Long Pre-Alarm Area" (System Menu
Data Management Setting for Main Memory
Change Partition Setting).
• When the long pre-alarm recording is started during
normal recording, not all the camera numbers set for
long pre-alarm recording may be used for recording.
Setup Menu
Memory

Advertisement

Table of Contents
loading

Table of Contents