Dell UPS Management Software Installation
To install the software:
1 Start the vMA 4.x guest operating system.
2 Download the software from the Dell Web site (support.dell.com) or from the CD (F618R A04 or
higher) provided with the UPS.
3 Upload the software from Windows to vMA 4.x using WinSCP tools.
4 Copy the Linux and InstallerData files from the CD to vMA.
5 Enter the following commands to access the Linux and InstallerData files:
sudo chmod -R 777 Linux
sudo chmod -R 777 InstallerData
6 Enter the Linux path and then enter the following command to install the software:
cd Linux
sudo ./setup_console.bin
7 VMware ESXi 4.0 only. Edit the document "VMwareESXHosts" on the installation path.
Add all ESXi server host IP addresses, separated by spaces. Add the IP address of the ESXi server on
which VIMA/vMA is installed as the last entry.
Example: 172.18.127.13 172.18.127.12 172.18.127.11
NOTE:
To configure each server, see "vMA Configuration" on page 118.
Installation on a VMware ESXi Server
126